Objective assessment of vitiligo with a computerised digital imaging analysis system.

نویسندگان

  • Norashikin Shamsudin
  • Suraiya H Hussein
  • Hermawan Nugroho
  • Mohd Hani Ahmad Fadzil
چکیده

UNLABELLED An objective tool to quantify treatment response in vitiligo is currently lacking. This study aimed to objectively evaluate the treatment response in vitiligo by using a computerised digital imaging analysis system (C-DIAS) and to compare it with the physician's global assessment (PGA). Tacrolimus ointment 0.1% (Protopic; Astellas Pharma Tech,Toyama, Japan) was applied twice daily on selected lesions which were photographed every 6 weeks for 24 weeks. The primary efficacy end-point was the mean percentage of repigmentation (MPR), as assessed by the digital method (MPR-C-DIAS) or by the PGA. The response was categorised into none (0%), mild (1-25%), moderate (26-50%), good (51-75%) and excellent (76-100%). MPR-C-DIAS Out of 56 patients, 44 (79%) responded. Overall, the response was mild in 22 (39%), moderate in 21(40%) and good in one (2%) patient(s). A total of 39 (70%) patients responded as measured by PGA. The repigmentation was mild in 27(48%), moderate in 10 (18%) and good to excellent in two (4%) patients. The κ test of consistency was 0.17 (P = 0.053), which shows poor agreement between the two assessment methods, although this is not statistically significant. The C-DIAS can be used to perform an objective analysis of repigmentation or depigmentation in vitiligo skin lesions in response to treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology

  Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and pr...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Disease Severity Indexes and Treatment Evaluation Criteria in Vitiligo

There is a current lack of consensus regarding methods of assessment of vitiligo. Recently, the Vitiligo Area Scoring Index (VASI) and the Vitiligo European Task Force (VETF) were proposed to offer more accurate measures of disease severity indexes and treatment evaluation criteria. It would make sense to combine the VASI with the VETF system. We proposed an original scale for treatment evaluat...

متن کامل

Image quality assessment in digital radiography systems- A Pehamed FLUORAD A+D phantom study

Introduction: The use of digital radiography systems has become more common all around the world. Ideal situation in radiography is to maximize the image quality while minimizing the patient dose. The purpose of this study was to compare image quality and radiation dose in different digital radiography systems. Materials and Methods: Images of Pehamed FLUORAD ...

متن کامل

Design and Manipulation 3D Imaging System by using Photodiode Grid

Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Australasian journal of dermatology

دوره 56 4  شماره 

صفحات  -

تاریخ انتشار 2015