Retrieval and analysis of particulate debris after saphenous vein graft intervention.
نویسندگان
چکیده
OBJECTIVES This study was designed to evaluate the composition and quantity of particulate debris resulting from vein graft intervention. BACKGROUND Distal embolization and "no reflow" are frequent and important complications resulting from angioplasty of diseased saphenous vein grafts. Little is known about the composition and quantity of embolic particulate debris associated with vein graft intervention, and no intervention has been shown to protect against its clinical consequences. METHODS A catheter system, designed to contain, retrieve and protect against distal embolization of this material, was evaluated during 27 percutaneous interventional saphenous vein graft procedures. Clinical, angiographic and pathologic analyses were performed. RESULTS The duration of distal graft occlusion required to allow intervention and subsequent debris removal was 150 +/- 54 s, decreasing as experience was gained. Thrombolysis in Myocardial Infarction trial (TIMI) flow grade increased from 2.6 +/- 0.8 to 3.0 +/- 0.0. Creatine kinase (CK) rose above normal in three patients (11.1%) exceeding 3x normal in one (3.7%) resulting in the diagnosis of non-Q-myocardial infarction. Particulate material was identified following 21 of 23 procedures suitable for analysis. Particle size was 204 +/- 57 microm in the major axis and 83 +/- 22 microm in the minor axis. Particles consisted predominantly of soft acellular atheromatous material, such as that typically found under a fibrous cap. Semiquantitative analysis suggested that the quantity of particulate material was less following stenting than following balloon dilation. CONCLUSIONS Particulate matter is commonly present following routine angioplasty and stenting of saphenous vein grafts. Containment, retrieval and analysis of this particulate debris are all feasible. Comparison to prior clinical experience is limited by small sample size. However, to the extent that these particles may contribute to distal embolization, no-reflow and infarction, such a system may contribute to the reduction of complications following vein graft intervention.
منابع مشابه
An update on herpes virus infections in graft recipients.
percutaneous coronary and carotid interventions. Curr Control Trials Cardiovasc Med 2001; 2: 286–291 11. Angelini A, Reimers B et al. Cerebral protection during carotid artery stenting. Stroke 2002; 33: 456–461 12. Webb JG, Carere RGC, Virmani R et al. Retrieval and analysis of particulate debris after saphenous vein graft intervention. J Am Col Cardiol 1999; 34: 468–475 13. Baim DS, Wahr D, Ge...
متن کاملEmbolic protection with filtering or occlusion balloons during saphenous vein graft stenting retrieves identical volumes and sizes of particulate debris.
BACKGROUND Distal embolization of plaque particulate liberated during stenting may cause periprocedural complications. The number, size, and volume of debris released during stenting, however, have not been quantified, rendering embolic protection approaches empiric. We used a novel method of microparticle size assessment to measure volume and characterize individual sizes of particles captured...
متن کاملCoronary aspirate TNFα reflects saphenous vein bypass graft restenosis risk in diabetic patients
BACKGROUND Patients with diabetes mellitus (DM) have an increased risk for periprocedural complications and adverse cardiac events after percutaneous coronary intervention. We addressed the potential for coronary microvascular obstruction and restenosis in patients with and without DM undergoing stenting for saphenous vein bypass graft (SVG) stenosis under protection with a distal occlusion/asp...
متن کاملPrevention of distal embolization during coronary angioplasty in saphenous vein grafts and native vessels using porous filter protection.
BACKGROUND Although distal embolization and the "no-reflow" phenomenon are well described in saphenous vein graft (SVG) interventions, the frequency, magnitude, and characterization of embolized debris have not been evaluated in routine coronary interventions. A unique embolus protection device described herein provides a means of containing and retrieving plaque material dislodged during percu...
متن کاملMajor Leg Wound Complications After Saphenous Vein Harvest for Coronary Revascularization
Background: Major leg wound complications after coronary artery bypass graft procedures are infrequent and few are reported in the litrature.We present our experience in treating 30 patients with major leg wound complications after coronary revascularization procedures. Materials and Methods: A retrospective review of 2100 bypass procedures with saphenous veingraft performed over a 5-years p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 34 2 شماره
صفحات -