Dolphin hearing during echolocation: evoked potential responses in an Atlantic bottlenose dolphin (Tursiops truncatus).

نویسندگان

  • Songhai Li
  • Paul E Nachtigall
  • Marlee Breese
چکیده

Auditory evoked potential (AEP) responses were recorded during echolocation in an Atlantic bottlenose dolphin (Tursiops truncatus) trained to accept suction-cup EEG electrodes and detect targets by echolocation. AEP recording was triggered by the echolocation clicks of the animal. Three targets with target strengths of -34, -28 and -22 dB were used at a target distance of 2 to 6.5 m for each target. The results demonstrated that the AEP appeared to both outgoing echolocation clicks and echoes during echolocation, with AEP complexes consisting of alternative positive and negative waves. The echo-related AEP amplitudes were obviously lower than the outgoing click-related AEP amplitudes for all the targets at the investigated target distances. However, for targets with target strengths of -22 and -28 dB, the peak-to-peak amplitudes of the echo-related AEPs were dependent on the target distances. The echo-related AEP response amplitudes increased at further target distances, demonstrating an overcompensation of echo attenuation with target distance in the echo-perception system of the dolphin biosonar. Measurement and analysis of outgoing click intensities showed that the click levels increased with target distance (R) by a factor of approximately 10 to 17.5 logR depending on target strength. The results demonstrated that a dual-component biosonar control system formed by intensity compensation behavior in both the transmission and receiving phases of a biosonar cycle exists synchronously in the dolphin biosonar system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hearing Sensation Levels of Emitted Biosonar Clicks in an Echolocating Atlantic Bottlenose Dolphin

Emitted biosonar clicks and auditory evoked potential (AEP) responses triggered by the clicks were synchronously recorded during echolocation in an Atlantic bottlenose dolphin (Tursiops truncatus) trained to wear suction-cup EEG electrodes and to detect targets by echolocation. Three targets with target strengths of -34, -28, and -22 dB were used at distances of 2 to 6.5 m for each target. The ...

متن کامل

On Novel Reception Models for Bottlenose Dolphin Echolocation

Bottlenose dolphin (Tursiops truncatus) echolocation resolution greatly exceeds measured beampattern and conventional hearing model performance. We explore the idea that teeth might aid conventional hearing. Nerve conduction requires neural delay lines, a requisite that might be met by unexplained specialised cell arrangements already reported. Jawbone resonance displays selectivity at 25-35 de...

متن کامل

A biomimetic projector with high subwavelength directivity based on dolphin biosonar

Articles you may be interested in Tracking dolphin whistles using an autonomous acoustic recorder array Depth dependent variation of the echolocation pulse rate of bottlenose dolphins (Tursiops truncatus) Bottlenose dolphins (Tursiops truncatus) moan as low in frequency as baleen whales Feeding at a high pitch: Source parameters of narrow band, high-frequency clicks from echolocating offshore h...

متن کامل

Hearing Loss in Stranded Odontocete Dolphins and Whales

The causes of dolphin and whale stranding can often be difficult to determine. Because toothed whales rely on echolocation for orientation and feeding, hearing deficits could lead to stranding. We report on the results of auditory evoked potential measurements from eight species of odontocete cetaceans that were found stranded or severely entangled in fishing gear during the period 2004 through...

متن کامل

Modeling the detection range of fish by echolocating bottlenose dolphins and harbor porpoises.

The target strength as a function of aspect angle were measured for four species of fish using dolphin-like and porpoise-like echolocation signals. The polar diagram of target strength values measured from an energy flux density perspective showed considerably less fluctuation with azimuth than would a pure tone pulse. Using detection range data obtained from dolphin and porpoise echolocation e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of experimental biology

دوره 214 Pt 12  شماره 

صفحات  -

تاریخ انتشار 2011