Correction: Visualization of the intracavitary blood flow in systemic ventricles of Fontan patients by contrast echocardiography using particle image velocimetry

نویسندگان

  • Konstantinos Lampropoulos
  • Werner Budts
  • Alexander Van de Bruaene
  • Els Troost
  • Joost P van Melle
چکیده

Following publication of our article [1] the authors noted that the legends for Figure 1 and Figure 2 were incorrect. The correct legend for Figure 1 is: Sequence analysis of systemic ventricular flow during systole and diastole in Fontan patients. The vortex from the Fontan group was consistently shorter, wider and rounder. The vortices were located at the centre of the left ventricle throughout diastole and systole and did not redirect flow in a coherent, sequential fashion as in controls. The location, shape and sphericity of the main vortices differ clearly from controls in all cardiac cycle [early diastole(A), late diastole(B), ejection (C)]. The correct legend for Figure 2 is: Sequence analysis of systemic ventricular flow during systole and diastole in controls. The vortex from the control group was compact, elliptically shaped, and located apically. The location, shape and sphericity of the main vortices differ clearly from the Fontan group in all cardiac cycle [early diastole(A), late diastole(B), ejection (C)]. It was also noted the legends for the Additional file 1 and Addition file 2 were also incorrect: The correct legend for Additional file 1 is: The flow patterns of a 38 year old female without cardiac abnormalities The correct legend for Additional file 2 is: The flow pattern of a 29 year old male with Fontan circulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visualization of the intracavitary blood flow in systemic ventricles of Fontan patients by contrast echocardiography using particle image velocimetry

BACKGROUND Flow patterns in univentricular hearts may have clinical value. Therefore, it is our objective to asses and characterize vortex flow patterns with Fontan circulation in comparison with healthy controls. METHODS Twenty-three patients (8 Fontan and 15 normal patients) underwent echocardiography with intravenous contrast agent (Sonovue®) administration. Dedicated software was used to ...

متن کامل

Heat Transfer Enhancement of a Flat Plate Boundary Layer Distributed by a Square Cylinder: Particle Image Velocimetry and Temperature-Sensitive Paint Measurements and Proper Orthogonal Decomposition Analysis

The current empirical study was conducted to investigate the wall neighborhood impact on the two-dimensional flow structure and heat transfer enhancement behind a square cylinder. The low- velocity open-circle wind tunnel was used to carry out the study tests considering the cylinder diameter (D)-based Reynolds number (ReD) of 5130. The selected items to compare were different gap he...

متن کامل

Simulation and patient studies of scatter correction in cardiac SPECT imaging

Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...

متن کامل

Comparisons of Experimental and Simulated Velocity Fields in Membrane Module Spacers

Spacers are used in spiral wound and plate and frame membrane modules to create flow channels between adjacent membrane layers and mix fluid within the flow channel. Flow through the spacer has a significant beneficial impact on mixing and resulting mass transfer rates but is accompanied by an undesirable increase in pressure drop. Computational Fluid Dynamics (CFD) is a common tool used to eva...

متن کامل

Characterization and quantification of vortex flow in the human left ventricle by contrast echocardiography using vector particle image velocimetry.

OBJECTIVES The aims of this study were to: 1) assess the feasibility of left ventricular (LV) vortex flow analysis using contrast echocardiography (CE); and 2) characterize and quantify LV vortex flow in normal subjects and patients with LV systolic dysfunction. BACKGROUND Vortices that form during LV filling have specific geometry and anatomical locations that are critical determinants of di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2012