Rapid determination of twenty amino acids by gas chromatography.

نویسندگان

  • J P Hardy
  • S L Kerrin
چکیده

greater than the response of similarly treated blanks at the 5-gg level and 400 times greater than the response of methanol to flame ionization detection (1 ,5 ) . The compound in which the methanol is to be determined, must be somewhat water soluble. Complete dissolution of the sample weight taken in the 1-ml water-urea mixture used is necessary to free the methanol for subsequent reaction. Accuracy. The results of methanol spikes in Isohumulone and 3-hydroxy-2-methy1-4H-pyran-4-one are given in Tables I11 and 1V. The recoveries were between 106 and 128%. The Isohumulone samples tested had between 12 and 24 ppm methanol whereas the 3-hydroxy-2-methyl-4H-pyran-4-one samples had between 150 and 600 ppm methanol. The standard curve for methanol in Isohumulone and 3-hydroxy2-methyl-4H-pyran-4-one is shown in Figure 1. A typical elution curve for methanol in Isohumulone is shown in Figure 2. The precision of the procedure is f 10%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of amino acid thiohydantoins directly by thin-layer chromatography and indirectly by gas-liquid chromatography after hydrolysis.

A method is described for the identification of amino acid thiohydantoins by two-dimensional t.l.c. An indirect method for the determination of amino acid thiohydantoins is described which, after hydrolysis, the corresponding amino acids are determined by g.l.c.

متن کامل

Amino Acid Profiling by Reactive Desorption Electrospray Ionization Tandem Mass Spectrometry (DESI-MS/MS)

Desorption electrospray ionization mass spectrometry (DESI MS) has gained significant recognition over the past few years because of its simplicity and rapid throughput capabilities, allowing for the direct analysis of samples with a wide variety of sizes, shapes, and chemistries. Addition of various reagents into the DESI spray solvent enables atmospheric pressure ion molecule reactions betwee...

متن کامل

AMINO ACIDS Gas Chromatography

New York: John Wiley. Grob RL (ed.) (1995) Modern Practice of Gas Chromatography, 3rd edn. New York: John Wiley. Heftmann E (ed.) (1992)Chromatography, 5th edn. Part B: Applications. (Journal of ChromatographyLibrary, Vol. 51B). Amsterdam: Elsevier. Hyver KJ and Sandra P (eds) (1989) High Resolution Gas Chromatography, 3rd edn. Delaware: Hewlett-Packard. Kataoka H (1996) Derivatization reaction...

متن کامل

Two-dimensional paper chromatographic determination of amino acids in urine.

DENT (1) introduced paper chromatography for tile ilivestigatioll of amino-aciduria in 1948. However, his one-dimensional system yielded inadequate separation, and his two-dimensional method required 3 days. Since then, technics utilizing gas chromatography (2-4), thin layer chromatography, column chromatography, and high voltage electrophoresis (5-7) have been published for tile determination ...

متن کامل

Development and Validation of a GC-FID Method for Diagnosis of Methylmalonic Acidemia

Background: Urinary organic acids are water-soluble intermediates and end products of the metabolism of amino acids, carbohydrates, lipids, and a number of other metabolic processes. In the hereditary diseases known as organic acidurias, an enzyme or co-factor defect in a metabolic pathway leads to the accumulation and increased excretion of one or more of these acidic metabolites. Gas chromato...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 44 8  شماره 

صفحات  -

تاریخ انتشار 1972