A laminar flow unit for the care of critically ill newborn infants

نویسندگان

  • Jose MR Perez
  • Sergio G Golombek
  • Carlos Fajardo
  • Augusto Sola
چکیده

INTRODUCTION Medical and nursing care of newborns is predicated on the delicate control and balance of several vital parameters. Closed incubators and open radiant warmers are the most widely used devices for the care of neonates in intensive care; however, several well-known limitations of these devises have not been resolved. The use of laminar flow is widely used in many fields of medicine, and may have applications in neonatal care. OBJECTIVE To describe the neonatal laminar flow unit, a new equipment we designed for care of ill newborns. METHODS The idea, design, and development of this device was completed in Sao Paulo, Brazil. The unit is an open mobile bed designed with the objective of maintaining the advantages of the incubator and radiant warmer, while overcoming some of their inherent shortcomings; these shortcomings include noise, magnetic fields and acrylic barriers in incubators, and lack of isolation and water loss through skin in radiant warmers. The unit has a pump that aspirates environmental air which is warmed by electrical resistance and decontaminated with High Efficiency Particulate Air Filter (HEPA) filters (laminar flow). The flow is directed by an air flow directioner. The unit has an embedded humidifier to increase humidity in the infant's microenvironment and a servo control mechanism for regulation of skin temperature. RESULTS The laminar flow unit is open and facilitates access of care providers and family, which is not the case in incubators. It provides warming by convection at an air velocity of 0.45 m/s, much faster than an incubator (0.1 m/s). The system provides isolation 1000 class (less than 1,000 particles higher than 0.3 micron per cubic feet at all times). This is much more protection than an incubator provides and more than radiant warmers, which have no isolation whatsoever. Additionally, it provides humidification of the newborn's microenvironment (about 60% relative humidity), which is impossible with a radiant warmer, which produces high water body loss. It has no mechanical barriers like acrylic walls, its magnetic field is lower than an incubator (0.25 μt versus 1.2 μt), and the noise is minimal compared to incubators. The unit is also able to provide controlled total body hypothermia, which is not possible with either of the other two units. CONCLUSION The laminar flow unit for neonatal care is a novel device which we recently developed. The introduction of laminar flow technology represents a real innovation in the neonatal field. We have described the various components of the unit and the potential advantages for management of ill neonates. This will hopefully lead to improved clinical outcomes and more effective neonatal management and safety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Nutritional Status in a Teaching Hospital Neonatal Intensive Care Unit

Background:Extrauterine growth restriction remains a common and serious problem in newborns especially who are small, immature, and critically ill. Very low birth weight infants (VLBW) had 97% and 40% growth failure at 36 weeks and 18-22 months post-conceptual age respectively. The postnatal development of premature infants is critically dependent on an adequate nutritional intake that mimics a...

متن کامل

Comparison of the Umbilical Cord Bacterial Colonization in Newborn Infants Rooming in with Mothers and Neonates Admitted to Neonatal Intensive Care Unit

Background Bacterial colonization during and shortly after birth are common in newborn infants. The aim of this study was to determine the umbilical cord bacterial colonization in newborn infants rooming in with mothers and neonates admitted to neonatal intensive care unit (NICU). Materials and Methods In a cross-sectional study, 180 newborn infants were studied in three groups including: newbo...

متن کامل

Islam-Based Caring for the Harmony of Life among Moslem Critically Ill Patients

Background: The application of more humanized approaches in the caring process of the Intensive Care Unit (ICU) patients with the aim of improving the quality of care has been given a growing attention However, there are limited studies regarding the Islam-based caring for the Moslem populations in Indonesia. Aim: This study aimed to explore and describe the caring actions employed by nurses to...

متن کامل

The interfacility transport of critically ill newborns.

The practice of paediatric/neonatal interfacility transport continues to expand. Transport teams have evolved into mobile intensive care units capable of delivering state-of-the-art critical care during paediatric and neonatal transport. While outcomes are best for high-risk infants born in a tertiary care setting, high-risk mothers often cannot be safely transferred. Their newborns may then ha...

متن کامل

Association between admission hypomagnesemia mortality or mortality of critically ill patients in intensive care unit

Background: Up to now there is no study evaluating correlation between serum magnesium and morbidity or mortality in patients admitted in intensive care unit. The aim of this study is to determine the prevalence of hypomagnesemia in critically ill patients and to evaluate its association with organ dysfunction, hospitalization period and mortality. Methods: We conducted a retrospective trial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2013