Creating hemodynamic atlases of cardiac 4D flow MRI

نویسندگان

  • Merih Cibis
  • Mariana Bustamante
  • Jonatan Eriksson
  • Carl‐Johan Carlhäll
  • Tino Ebbers
چکیده

PURPOSE Hemodynamic atlases can add to the pathophysiological understanding of cardiac diseases. This study proposes a method to create hemodynamic atlases using 4D Flow magnetic resonance imaging (MRI). The method is demonstrated for kinetic energy (KE) and helicity density (Hd ). MATERIALS AND METHODS Thirteen healthy subjects underwent 4D Flow MRI at 3T. Phase-contrast magnetic resonance cardioangiographies (PC-MRCAs) and an average heart were created and segmented. The PC-MRCAs, KE, and Hd were nonrigidly registered to the average heart to create atlases. The method was compared with 1) rigid, 2) affine registration of the PC-MRCAs, and 3) affine registration of segmentations. The peak and mean KE and Hd before and after registration were calculated to evaluate interpolation error due to nonrigid registration. RESULTS The segmentations deformed using nonrigid registration overlapped (median: 92.3%) more than rigid (23.1%, P < 0.001), and affine registration of PC-MRCAs (38.5%, P < 0.001) and affine registration of segmentations (61.5%, P < 0.001). The peak KE was 4.9 mJ using the proposed method and affine registration of segmentations (P = 0.91), 3.5 mJ using rigid registration (P < 0.001), and 4.2 mJ using affine registration of the PC-MRCAs (P < 0.001). The mean KE was 1.1 mJ using the proposed method, 0.8 mJ using rigid registration (P < 0.001), 0.9 mJ using affine registration of the PC-MRCAs (P < 0.001), and 1.0 mJ using affine registration of segmentations (P = 0.028). The interpolation error was 5.2 ± 2.6% at mid-systole, 2.8 ± 3.8% at early diastole for peak KE; 9.6 ± 9.3% at mid-systole, 4.0 ± 4.6% at early diastole, and 4.9 ± 4.6% at late diastole for peak Hd . The mean KE and Hd were not affected by interpolation. CONCLUSION Hemodynamic atlases can be obtained with minimal user interaction using nonrigid registration of 4D Flow MRI. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1389-1399.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of left ventricular hemodynamic forces in healthy subjects and patients with dilated cardiomyopathy using 4D flow MRI.

We hypothesized that the direction of global left ventricular (LV) hemodynamic forces during diastolic filling are concordant with the main flow axes in normal LVs, but that this pattern would be altered in dilated and dysfunctional LVs. Therefore, we aimed to assess the LV hemodynamic filling forces in a group of healthy subjects and compare them to the results from a group of patients with di...

متن کامل

Hemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications

Recent improvements have been made to the use of time-resolved, three-dimensional phase-contrast (PC) magnetic resonance imaging (MRI), which is also named four-dimensional (4D) PC-MRI or 4D flow MRI, in the investigation of spatial and temporal variations in hemodynamic features in cardiovascular blood flow. The present article reviews the principle and analytical procedures of 4D PC-MRI. Vari...

متن کامل

Advanced Analysis Techniques for Intra-cardiac Flow Evaluation from 4D Flow MRI

PURPOSE OF THE REVIEW Time-resolved 3D velocity-encoded MR imaging with velocity encoding in three directions (4D Flow) has emerged as a novel MR acquisition technique providing detailed information on flow in the cardiovascular system. In contrast to other clinically available imaging techniques such as echo-Doppler, 4D Flow MRI provides the 3D Flow velocity field within a volumetric region of...

متن کامل

Compressed sensing accelerated 4D-flow MRI in the murine aorta

Background A key determinant of cardiac pump function is the complex interplay between the heart and the arterial system, (i. e. arterio-ventricular coupling). Aging and pathological changes such as atherosclerosis alter elastic properties of the vessel wall, and therefore adversely influence hemodynamic parameters. Mice are commonly used to study cardiovascular disease, but very little has bee...

متن کامل

A practical introduction to the hemodynamic analysis of the cardiovascular system with 4D Flow MRI.

The 4D Flow MRI technique provides a three-dimensional representation of blood flow over time, making it possible to evaluate the hemodynamics of the cardiovascular system both qualitatively and quantitatively. In this article, we describe the application of the 4D Flow technique in a 3T scanner; in addition to the technical parameters, we discuss the advantages and limitations of the technique...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 46  شماره 

صفحات  -