Cardiac cine with ART for radial parallel imaging reconstruction
نویسندگان
چکیده
Background It was noted early-on that non-Cartesian parallel imaging is achievable by solving the k-space data consistency equation, with inclusion of coil sensitivity profiles [1]. This iterative method which uses gridding is successful [2,3], as is radial GRAPPA [4]. Here we present the first results of algebraic reconstruction technique (ART) [5,6] which also enforces data consistency. The use of ART with coil-map constraints for radial MRI reconstruction has only recently been described [5] and has not been explored for clinical applications.
منابع مشابه
Radial simultaneous multi slice imaging for rapid cardiac imaging
Background It may be possible to more rapidly acquire cine, cardiac perfusion, and Late Gadolinium Enhancement (LGE) images for “free” with Simultaneous Multi-Slice (SMS) methods. With SMS imaging, multiple slices are simultaneously excited and acquired. Here we explore the application of an undersampled radial SMS approach termed Controlled Aliasing In Parallel Imaging results in higher accele...
متن کاملA comparison of real-time radial GRAPPA and standard cine imaging for the evaluation of cardiac function in children and young adults
Background Segmented balanced steady state free precession (bSSFP) cine imaging is the gold standard MRI technique for assessing ventricular systolic function. The image acquisition involves ECG gating and is ideally performed during breath-hold to reduce artifacts from myocardial and respiratory motion. Real-time radial imaging with parallel imaging technique GRAPPA reconstruction (radial GRAP...
متن کاملCompression2: compressed sensing with compressed coil arrays
Background Imaging with large coil arrays is desirable for rapid imaging and high signal to noise ratio. Compressed sensing (CS) is a promising way to accelerate myocardial perfusion imaging [1]. However with increasing number of coils CS is costly in terms of memory and computation time. Coil compression methods for reconstructing cardiac cine data with parallel imaging have been proposed [2,3...
متن کاملRespiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.
A respiratory and cardiac self-gated free-breathing three-dimensional cine steady-state free precession imaging method using multiecho hybrid radial sampling is presented. Cartesian mapping of the k-space center along the slice encoding direction provides intensity-weighted position information, from which both respiratory and cardiac motions are derived. With in plan radial sampling acquired a...
متن کاملNonlinear profile order for 3D hybrid radial acquisition applied to self-gated free-breathing cardiac cine MRI
Background Self-gated free-breathing 3D cardiac cine MRI has been widely introduced, which provides similar image quality and functional measurements as breath-hold technique [1-3]. In self-gated free-breathing cardiac cine MRI, respiratory and cardiac motions are unpredictable during the acquisition especially in retrospective reconstruction. Therefore, nonuniform k-space distribution is a maj...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2013