Correction of MR image distortions induced by metallic objects using a 3D cubic B-spline basis set: application to stereotactic surgical planning.

نویسندگان

  • S Skare
  • J L R Andersson
چکیده

Metallic implants in MRI cause spin-echo (SE) images to be distorted in the slice and frequency-encoding directions. Chang and Fitzpatrick (IEEE Trans Med Imaging 1992;11:319-329) proposed a distortion correction method (termed the CF method) based on the magnitude images from two SE acquisitions that differ only in the polarity of the frequency-encoding and slice-selection gradients. In the present study we solved some problems with the CF method, primarily by modeling the field inhomogeneities as a single 3D displacement field built by 3D cubic B-splines. The 3D displacement field was applied in the actual distortion direction in the slice/frequency-encoding plane. To account for patient head motion, a 3D rigid body motion correction was also incorporated in the model. Experiments on a phantom containing an aneurysm clip showed that the knot spacing between the B-splines is a very important factor in both the final image quality and the processing speed. Depending on the knot spacing and the image volume size, the number of unknowns range from a few thousands to over 100,000, leading to processing times ranging from minutes to days. Optimal knot spacing, a means of increasing the processing speed, and other parameters are investigated and discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

Application of linear combination between cubic B-spline collocation methods with different basis for solving the KdV equation

In the present article, a numerical method is proposed for the numerical solution of the KdV equation by using a new approach by combining cubic B-spline functions. In this paper we convert the KdV equation to system of two equations. The method is shown to be unconditionally stable using von-Neumann technique. To test accuracy the error norms L2, L∞ are computed. Three invariants of motion are...

متن کامل

3D Reconstruction Using Cubic Bezier Spline Curves and Active Contours (Case Study)

Introduction 3D reconstruction of an object from its 2D cross-sections (slices) has many applications in different fields of sciences such as medical physics and biomedical engineering. In order to perform 3D reconstruction, at first, desired boundaries at each slice are detected and then using a correspondence between points of successive slices surface of desired object is reconstructed. Mate...

متن کامل

Solving a nonlinear inverse system of Burgers equations

By applying finite difference formula to time discretization and the cubic B-splines for spatial variable, a numerical method for solving the inverse system of Burgers equations is presented. Also, the convergence analysis and stability for this problem are investigated and the order of convergence is obtained. By using two test problems, the accuracy of presented method is verified. Additional...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 54 1  شماره 

صفحات  -

تاریخ انتشار 2005