3D digital subtraction angiography of intracranial aneurysms: comparison of flat panel detector with conventional image intensifier TV system using a vascular phantom.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Compared with the image intensifier (I.I.)-TV system, the flat panel detector (FPD) system of direct conversion type has several theoretic advantages, such as higher spatial resolution, wide dynamic range, and no image distortion. The purpose of this study was to compare the image quality of 3D digital subtraction angiography (DSA) in the FPD and conventional I.I.-TV systems using a vascular phantom. MATERIALS AND METHODS An anthropomorphic vascular phantom was designed to simulate the various intracranial aneurysms with aneurysmal bleb. The tubes of this vascular phantom were filled with 2 concentrations of contrast material (300 and 150 mg I/mL), and we obtained 3D DSA using the FPD and I.I.-TV systems. First, 2 blinded radiologists compared the volume-rendering images for 3D DSA on the FPD and I.I.-TV systems, looking for pseudostenosis artifacts. Then, 2 other radiologists independently evaluated both systems for the depiction of the simulated aneurysm and aneurysmal bleb using a 5-point scale. RESULTS For the degree of the pseudostenosis artifacts at the M1 segment of the middle cerebral artery at 300 mg I/mL, 3D DSA with FPD system showed mild stenoses, whereas severe stenoses were observed at 3D DSA with I.I.-TV system. At both concentrations, the FPD system was significantly superior to I.I.-TV system regarding the depiction of aneurysm and aneurysmal bleb. CONCLUSION Compared with the I.I.-TV system, the FPD system could create high-resolution 3D DSA combined with a reduction of the pseudostenosis artifacts.
منابع مشابه
Reduction of radiation dose for cerebral angiography using flat panel detector of direct conversion type: a vascular phantom study.
BACKGROUND AND PURPOSE Compared with image intensifier television (I.I.-TV) system, an angiography system using the flat panel detector (FPD) of direct conversion type has a high spatial resolution, which may improve image quality, reduce patient exposure, or both. Our purpose was to evaluate the detection of simulated aneurysmal blebs under dose reduction with the FPD system in comparison with...
متن کامل[Evaluation of FOV size on cerebral three-dimensional rotational digital subtraction angiography with flat panel detector system].
In interventional neuroradiology, three-dimensional rotational digital subtraction angiography (3D-DSA) is very useful for the spatial grasp of the location and size of an intracranial cerebral aneurysm. The purposes of this study were to evaluate the property of three-dimensional image dependence on the respective field of view (FOV) size in a flat-panel detector (FPD) using vessel phantoms, a...
متن کاملApplication of live 3D tools in vascular interventional radiology
An accurate morphological assessment of blood vessels and their relationship with interventional devices is essential in the management of vascular lesions, and digital subtraction angiography (DSA) has had a central role in the deployment of interventional procedures. The introduction of three-dimensional rotational angiography (3D RA) and flat panel detector technology has further contributed...
متن کاملSubtraction 3D CT angiography with the orbital synchronized helical scan technique for the evaluation of postoperative cerebral aneurysms treated with cobalt-alloy clips.
BACKGROUND AND PURPOSE CT angiography (CTA) has been used for the evaluation of intracranial aneurysms and recently has been applied to assess postoperative aneurysms treated with titanium-alloy clips. We investigated the clinical usefulness of subtraction CTA by using the orbital synchronized helical scan technique (OSHST) for evaluating intracranial aneurysms surgically treated with cobalt-al...
متن کامل3D rotational digital subtraction angiography may underestimate intracranial aneurysms: findings from two basilar aneurysms.
3D digital subtraction angiography (DSA) allows clinicians to review intracranial aneurysms and other vascular lesions. We report 2 basilar aneurysms that were imaged by both 3D DSA and DynaCT. These 2 techniques produced very different aneurysm appearances. Anterior portions of the aneurysms were invisible on 3D DSA but were revealed by DynaCT. These aneurysms appeared to have been flattened b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 28 5 شماره
صفحات -
تاریخ انتشار 2007