Beyond noise power in 3D computed tomography: the local NPS and off-diagonal elements of the Fourier domain covariance matrix.
نویسندگان
چکیده
PURPOSE To investigate the correlation and stationarity of noise in volumetric computed tomography (CT) using the local discrete noise-power spectrum (NPS) and off-diagonal elements of the covariance matrix of the discrete Fourier transform of noise-only images (denoted Σ(DFT)). Experimental conditions were varied to affect noise correlation and stationarity, the effects were quantified in terms of the NPS and Σ(DFT), and practical considerations in CT performance characterization were identified. METHODS Cone-beam CT (CBCT) images were acquired using a benchtop system comprising an x-ray tube and flat-panel detector for a range of acquisition techniques (e.g., dose and x-ray scatter) and three phantom configurations hypothesized to impart distinct effects on the NPS and Σ(DFT): (A) air, (B) a 20-cm-diameter water cylinder with a bowtie filter, and (C) the cylinder without a bowtie filter. The NPS and off-diagonal elements of the Σ(DFT) were analyzed as a function of position within the reconstructions. RESULTS The local NPS varied systematically throughout the axial plane in a manner consistent with changes in fluence transmitted to the detector and view sampling effects. Variability in fluence was manifest in the NPS magnitude-e.g., a factor of ~2 variation in NPS magnitude within the axial plane for case C (cylinder without bowtie), compared to nearly constant NPS magnitude for case B (bowtie filter matched to the cylinder). View sampling effects were most prominent in case A (air) where the variance increased at greater distance from the center of reconstruction and in case C (cylinder) where the NPS exhibited correlations in the radial direction. The effects of detector lag were observed as azimuthal correlation. The cylinder (without bowtie) had the strongest nonstationarity because of the larger variability in fluence transmitted to the detector. The diagonal elements of the Σ(DFT) were equivalent to the NPS estimated from the periodogram, and the average off-diagonal elements of the Σ(DFT) exhibited amplitude of ~1% of the NPS for the experimental conditions investigated. Furthermore, the off-diagonal elements demonstrated fairly long tails of nearly constant amplitude, with magnitude somewhat reduced for experimental conditions associated with greater stationarity (viz., lower Σ(DFT) tails for cases A and B in comparison to case C). CONCLUSIONS Volumetric CT exhibits nonstationarity in the NPS as hypothesized in relation to fluence uniformity and view sampling. Measurement of the NPS should seek to minimize such changes in noise correlations and include careful reporting of experimental conditions (e.g., phantom design and use of a bowtie filter) and spatial dependence (e.g., analysis at fixed radius within a phantom). Off-diagonal elements of the Σ(DFT) similarly depend on experimental conditions and can be readily computed from the same data as the NPS. This work begins to check assumptions in NPS analysis examine the extent to which NPS is an appropriate descriptor of noise correlations, and investigate the magnitude of off-diagonal elements of the Σ(DFT). While the magnitude of such off-diagonal elements appears to be low, their cumulative effect on space-variant detectability remains to be investigated-e.g., using task-specific figures of merit.
منابع مشابه
Analysis of Image Noise in 3D Cone-Beam CT: Spatial and Fourier Domain Approaches under Conditions of Varying Stationarity
The statistical properties of medical images are central in characterizing the performance of imaging systems. The noise in cone-beam CT (CBCT) is often characterized using Fourier-based metrics, such as the 3D noise-power spectrum (NPS). Under a stationarity assumption, the NPS provides a complete representation of the covariance of the images, since the covariance matrix of the Fourier transf...
متن کامل3D Models Recognition in Fourier Domain Using Compression of the Spherical Mesh up to the Models Surface
Representing 3D models in diverse fields have automatically paved the way of storing, indexing, classifying, and retrieving 3D objects. Classification and retrieval of 3D models demand that the 3D models represent in a way to capture the local and global shape specifications of the object. This requires establishing a 3D descriptor or signature that summarizes the pivotal shape properties of th...
متن کاملTheoretical Framework for the Dual-Energy Cone-Beam CT Noise-Power Spectrum, NEQ, and Tasked-Based Detectability Index
The optimization of dual-energy computed tomography (DE-CT) is challenged by the lack of a theoretical foundation for image quality. This work reports a cascaded systems analysis model that was used to derive signal and noise propagation in DE-CBCT in prevalent Fourier metrics such as the noise-power spectrum (NPS) and noise-equivalent quanta (NEQ). The model was validated in comparison to meas...
متن کاملQuantitative Non-diagonal Regulator Design for Uncertain Multivariable System with Hard Time-domain Constraints
In this paper a non-diagonal regulator, based on the QFT method, is synthesized for an uncertain MIMO plant whose output and control signals are subjected to hard time-domain constraints. This procedure includes the design of a non-diagonal pre-controller based on a new simple approach, followed by the sequential design of a diagonal QFT controller. We present a new formulation for the latter s...
متن کاملShearlet-Based Adaptive Noise Reduction in CT Images
The noise in reconstructed slices of X-ray Computed Tomography (CT) is of unknown distribution, non-stationary, oriented and difficult to distinguish from main structural information. This requires the development of special post-processing methods based on the local statistical evaluation of the noise component. This paper presents an adaptive method of reducing noise in CT images employing th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 39 6 شماره
صفحات -
تاریخ انتشار 2012