Influence of the site of measurement on the ability of plethysmographic variability index to predict fluid responsiveness.
نویسندگان
چکیده
BACKGROUND Plethysmographic variability index (PVI) is an accurate predictor of fluid responsiveness in mechanically ventilated patients. However, the site of measurement of the plethysmographic waveform impacts its morphology and its respiratory variation. The goal of this study was to investigate the ability of PVI to predict fluid responsiveness at three sites of measurement (the forehead, ear, and finger) in mechanically ventilated patients under general anaesthesia. METHODS We studied 28 subjects after induction of general anaesthesia. Subjects were monitored with a pulmonary artery catheter and three pulse oximeter sensors (the finger, ear, and forehead). Pulse pressure variation, central venous pressure, cardiac index (CI), and PVI measured at the forehead, ear, and finger (PVI(forehead), PVI(ear), and PVI(finger)) were recorded before and after fluid loading (FL). Subjects were responders to volume expansion if CI increased >15% after FL. RESULTS Areas under the receiver-operating curves to predict fluid responsiveness were 0.906, 0.880, and 0.836 for PVI(forehead), PVI(ear), and PVI(finger), respectively (P<0.05). PVI(forehead), PVI(ear), and PVI(finger) had a threshold value to predict fluid responsiveness of 15%, 16%, and 12% with sensitivities of 89%, 74%, and 74% and specificities of 78%, 74%, and 67%, respectively. CONCLUSIONS PVI can predict fluid responsiveness in anaesthetized and ventilated subjects at all three sites of measurement. However, the threshold values for predicting fluid responsiveness differ with the site of measurement. These results support the use of this plethysmographic dynamic index in the cephalic region when the finger is inaccessible or during states of low peripheral perfusion.
منابع مشابه
Clinical investigation of plethysmographic variability index: A derivative index of pulse oximetry in anesthetized dogs
Paranjape, Vaidehi V. M.S., Purdue University, August 2014. Clinical Investigation of Plethysmographic Variability Index: A Derivative Index of Pulse Oximetry in Anesthetized Dogs. Major Professor: Jeff C. Ko. Plethysmographic Variability Index (PVI) is a derivative index of pulse oximetry that allows evaluating an individual's intravascular volume status. Perfusion Index (PI) represents the st...
متن کاملPleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.
BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanicall...
متن کاملAccuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index.
BACKGROUND Respiratory variations in plethysmographic waveform amplitudes derived from pulse oximetry are believed to predict fluid responsiveness. The non-invasive pleth variability index (PVI) is a variable based on the calculation of changes in the perfusion index (PI). The aim of the following study was to examine whether the predictive power of PVI depends on different values of PI. METH...
متن کاملStroke volume variation and pleth variability index to predict fluid responsiveness during resection of primary retroperitoneal tumors in Hans Chinese.
Respiration variation in arterial pulse pressure (ΔPP) and pulse oximetry plethysmographic waveform amplitude (ΔPOP) are accurate predictors of fluid responsiveness in mechanically ventilated patients. We hypothesized that stroke volume variation (SVV) and pleth variability index (PVI) can predict fluid responsiveness in mechanically ventilated patients during major surgical procedures in H...
متن کاملPlethysmographic variability index (PVI) accuracy in predicting fluid responsiveness in anesthetized children.
INTRODUCTION Plethysmographic Variability Index (PVI) has been shown to accurately predict responsiveness to fluid loads in adults. The goal of this study was to evaluate PVI accuracy when predicting fluid responsiveness during noncardiac surgery in children. MATERIAL AND METHODS Children aged 2-10 years scheduled for noncardiac surgery under general anesthesia were included. PVI was assessed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 107 3 شماره
صفحات -
تاریخ انتشار 2011