Selective ratiometric detection of mercury(II) ions in water with an acridizinium-based fluorescent probe.

نویسندگان

  • Maoqun Tian
  • Heiko Ihmels
چکیده

The integration of a selective Hg2+ receptor unit, 1,4-dioxa-7,13-dithia-10-azacyclopentadecane, into the 9-aminoacridizinium fluorophore provides a fluorescent probe which allows a selective ratiometric detection of Hg2+ in water.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Terbium(III)/gold nanocluster conjugates: the development of a novel ratiometric fluorescent probe for mercury(II) and a paper-based visual sensor.

In this work, a novel ratiometric fluorescent probe was developed for rapid, highly accurate, sensitive and selective detection of mercury(II) (Hg(2+)) based on terbium(III)/gold nanocluster conjugates (Tb(3+)/BSA-AuNCs), in which bovine serum albumin capped gold nanoclusters (BSA-AuNCs) acted as the signal indicator and terbium(III) (Tb(3+)) was used as the build-in reference. Our proposed rat...

متن کامل

An ESIPT-based fluorescent probe for highly selective and ratiometric detection of mercury(II) in solution and in cells.

A novel ratiometric fluorescent Hg(2+) detecting system was rationally developed based on the typical excited state intramolecular proton transfer (ESIPT) characteristic of the latent fluorophore, 2-(1-(p-tolyl)-1H-phenanthro[9,10-d]imidazol-2-yl)phenol (Pol) and the Hg(2+)-mediated cleavage of the vinyl group. The probe responds selectively to Hg(2+) over various other metal ions with a larger...

متن کامل

A highly sensitive and selective detection of Hg(II) in 100% aqueous solution with fluorescent labeled dimerized Cys residues.

A simple design of a ratiometric fluorescent sensor for detecting Hg(II) ion in 100% aqueous solution was demonstrated, based on the structure of dimerized Cys residues with two dansyl fluorophores. The sensor highly sensitively and selectively detected mercury ion (K(d) = 41 nM) in 100% aqueous solution via a turn-on and ratiometric response. The sensor showed no interferences of other metal i...

متن کامل

An amine/imine functionalized microporous MOF as a new fluorescent probe exhibiting selective sensing of Fe3+ and Al3+ over mixed metal ions

Nowadays metal-organic frameworks with multiple luminescent centers are very fascinating as multifunctional luminescent material because of their luminescence properties, which could be systematically tuned by deliberate use of organic ligands and metal ions. In this research, we explored a microporous mixed-ligand MOF for highly selective and sensitive detection of metal ions. A two-fold inter...

متن کامل

Nanoparticles as scaffolds for FRET-based ratiometric detection of mercury ions in water with QDs as donors.

The quenching of quantum dots' emission by some analytes (Hg(2+), Pb(2+), etc.) has long been hindering the fabrication of QD-based 'turn-on' or ratiometric fluorescent sensors for these analytes. In this study, we demonstrate a facile solution for constructing a robust FRET-based ratiometric sensor for Hg(2+) detection in water with CdTe QDs as the donor. By using the reverse microemulsion app...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chemical communications

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2009