Direct determination of lead and cadmium in blood and urine by flameless atomic absorption spectrophotometry.

نویسندگان

  • V Lagesson
  • L Andrasko
چکیده

We describe procedures for direct determination of lead and cadmium in blood and urine by flameless atomic absorption spectrophotometry. Before analysis, the samples are pre-ashed in microboats in an ordinary laboratory oven. In this way, many samples can be prepared and pre-ashed simultaneously. We find the procedures presented in this work to be rapid, accurate, and precise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of urinary manganese by the direct chelation-extraction method and flameless atomic absorption spectrophotometry.

The direct chelation-extraction method, originally developed by Hessel (1968) for blood lead analysis, has been successfully applied to urinalysis for manganese. The analyses of 35 urine samples containing up to 100 microgram/1 of manganese from manganese-exposed workers showed that the data obtained by this method agree well with those by wet digestion-flame atomic absorption spectrophotometry...

متن کامل

[Direct determination of lead in blood by flameless atomic absorption spectrophotometry].

A simple and direct method for determining lead in blood by flameless atomic absorption spectrophotometry was developed by modifying the method of Hodges and Skelding (1983). In the present method, a graphite tube was coated with molybdenum and both Triton X-100 and phosphoric acid were added to heparinized whole blood. The calibration curve for lead determination, prepared by adding standard l...

متن کامل

Determination of platinum, palladium, and lead in biological samples by atomic absorption spectrophotometry.

A flameless atomic absorption method for the coextraction of platinum and palladium from biological and environmental samples by high molecular weight amine (HMWA) is given. Also, methods for lead determination in biological samples by use of extraction flameless analysis and direct aspiration-flame analysis are reported. A study of lead contamination of Vacutainer tubes is given.

متن کامل

Determination of diethyllead in the urine by flameless atomic absorption spectrometry.

A method for the determination of diethyllead in urine by flameless atomic absorption spectrometry after chelation with glyoxal-bis (2-hydroxyanil) and extraction of the formed complex with methyl isobutyl ketone is described. The method is specific in relation to both triethyllead and inorganic lead. The limit of detection was 3.2 micrograms Pb/l and the relative standard deviation in the conc...

متن کامل

Application of blood cadmium determination to industry using a punched disc technique.

A paper disc flameless atomic absorption spectroscopy (AAS) method is described for the determination of cadmium (Cd) in blood, enabling difficulties in sample preparation to be minimized. By control of the ashing step the matrix can be removed without loss of cadmium. Problems with the fast signal response during atomization can be met by spectral band width and temperature control. At the 106...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 11  شماره 

صفحات  -

تاریخ انتشار 1979