Assessment of an infant whole-body plethysmograph using an infant lung function model.

نویسندگان

  • B Reinmann
  • J Stocks
  • U Frey
چکیده

In order to facilitate international multicentre studies and improve the quality control of infant pulmonary function measurements, the European Respiratory Society-American Thoracic Society Task Force for infant lung function testing has recently developed specifications for standardized infant lung function equipment and software. A mechanical infant lung model analogue has been developed to assess whether infant lung function equipment is able to meet these requirements. However, the practical testing of infant lung function equipment using such models is highly complex because of the need to use very small pressure and flow changes, and the numerous potentially confounding factors associated with both the design of the device and the testing procedure. The aim of this study was to determine whether the infant lung model is capable of assessing the overall function of an whole-body infant- plethysmograph, using the only infant plethysmograph that was commercially available at the time as an example. The mechanical characteristics of the model such as vibrations or noise did not disturb the delicate plethysmographic measurements and thereby allowed a reliable assessment of the system. A series of tests revealed that the plethysmograph was able to measure airway resistance 1-3.5 kPa.L(-1).s with an accuracy of +/-2.5% and lung volumes 75-300 mL with an accuracy of +/-2.5% under in vitro conditions. To conclude, the infant lung model is a useful means of assessing the overall in vitro performance of infant whole-body plethysmographs, but thermal, mechanical and frequency response characteristics of such a device must be taken into account when interpreting the results of such assessments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Model of the Respiratory System in the Newborn Infant

A dynamic mathematical model is presented which successfully simulates the respiratory control system of the newborn infant in different physiological conditions. The primary objective in constructing this model has been to provide a simulation aid in the investigation of maturation of the respiratory system, and the respiratory disorders during the newborn period, without the need for invasive...

متن کامل

Congenital Cystic Adenomatoid Malformation (CCAM) of Lung in an Infant: A Case Report from Jammu & Kashmir, Northern India

Congenital cystic Adenomatoid malformation is a rare developmental abnormality of the lung occuring in 1-4/100000 live births.In most cases the outcome with CCAM in fetus is very good,while in some cases the outcome is very bad and can be life threatning for the fetus.we report here a case of 40 day old female infant who presented with worsening respiratory distress since birth and x ray and CT...

متن کامل

Comparison of airway measurements during influenza-induced tachypnea in infant and adult cotton rats

BACKGROUND Increased respiratory rate (tachypnea) is frequently observed as a clinical sign of influenza pneumonia in pediatric patients admitted to the hospital. We previously demonstrated that influenza infection of adult cotton rats (Sigmodon hispidus) also results in tachypnea and wanted to establish whether this clinical sign was observed in infected infant cotton rats. We hypothesized tha...

متن کامل

Evaluation of an Infant with Cholestasis and Congenital Hypopituitarism

We are reporting an infant with persistent abnormal liver function, neonatal jaundice, and intermittent hypoglycemia. Evaluation confirmed congenital hypopituitarism, in the absence of congenital anomalies and midline defect. His jaundice and abnormal liver function improved after treatment with Levothyroxine and hydrocortisone.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2001