The facet joint loading profile of a cervical intervertebral disc replacement incorporating a novel saddle-shaped articulation.

نویسندگان

  • Jonathan R Stieber
  • Martin Quirno
  • Mathew Kang
  • Anthony Valdevit
  • Thomas J Errico
چکیده

STUDY DESIGN Biomechanical study. OBJECTIVE To evaluate the cervical facet loading profile of an intervertebral cervical disc prosthesis incorporating a unique saddle-shaped articulation and to determine the effect of implantation of the prosthesis on both the loading curve and area distribution of facet loading, when compared with that of an intact specimen. SUMMARY OF BACKGROUND DATA This is the first study that examines the effect of implantation of a cervical disc replacement on the loading of the facet joints. METHODS Fresh-frozen ovine cervical spine specimens were used. Specimens were prepared and disarticulated to yield 6 functional spinal units, which were secured and mounted in a custom fixture on a material testing apparatus. A novel pressure sensor was constructed by combining a resistive ink thin film sensor with Fuji pressure-sensitive film. The sensor was calibrated before unilateral insertion into the cervical facet joint via a small arthrotomy. Specimens were tested in both intact condition and after surgical intervention consisting of discectomy and implantation of an intervertebral cervical disc prosthesis (CerviCore, Stryker Spine, Allendale, NJ). Specimens were tested in flexion, extension, and lateral bending to 3 Nm and in torsion to 2.5 Nm. At the termination of each loading profile, the load was maintained for 30 seconds to permit full exposure of the Fuji film. For each configuration, the maximum resultant load, load rate, and contact area pressure at the endpoint of the loading profile were determined. A paired Student t test was used to determine the differences between the intact specimen and the specimen with an implanted intervertebral disc prosthesis. RESULTS There were no statistically significant differences in mean or maximum pressures between the intact specimen and the specimen with an intervertebral disc in all loading configurations. Similarly, there was no significant difference in the total measured force between the groups in all loading configurations. There was no significant difference in contact areas between the groups in flexion, lateral bending, and torsion. When evaluated in extension, the intact specimen had a mean contact area of 0.8 cm compared with 0.5 cm for the intervertebral disc (P<0.02). CONCLUSIONS Biomechanical testing in an ovine model demonstrated no significant difference in measured facet pressures and forces between an intact native cervical disc specimen and a cervical intervertebral disc prosthesis using a saddle-shaped articulation. Peak and mean pressures were not demonstrated to be significantly different between the implanted and intact disc conditions. Implantation of the prosthesis resulted in a significant reduction of contact area under extension moments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiological Parameters of Undegenerated Cervical Vertebral Segments in a Korean Population

BACKGROUND Several scoring systems for cervical disc and facet joint degeneration, using radiography or computed tomography, have been developed and tested for reliability. However, definitions of disc height and facet joint space narrowing vary. To our knowledge, no study has reported quantitative data for normal radiologic values of the cervical spine in the Korean population. The purpose of ...

متن کامل

Effect of lumbar disc replacement on the height of the disc space and the geometry of the facet joints: a cadaver study.

In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation software applied to CT scans before and aft...

متن کامل

Cervical Disc Prosthesis Polyethylene Wear Following The ISO Cervical Test

Introduction: Cervical total disc replacement (TDR) procedures are an option for treatment of cervical spinal disc degeneration. The goal of TDR replacement is to replace the painful and degenerated TDR with a new bearing unit to enable pain free motion. A young and active patient population demands a proven durable replacement bearing surface to accomplish this goal. The wear of that surface m...

متن کامل

Computed Tomographic Evaluation of Degenerative Spine Changes in Patients with Obstructive Sleep Apnea Syndrome: A Case Control Study

Objective: Recently few studies have described presence of cervical spine anomalies in obstructive sleep apnoea syndrome (OSAS) patients. It is also reported that some cases of cervical spine pathologies and osteophytes producing obstructive sleep apnea. We aim to investigate the prevalence of facet joint arthrosis and degenerative disc disease (DDD) in cervical spine using computed tomography ...

متن کامل

Effect of Stress on Intervertebral Disc and Facet Joint of Novel Lumbar Spine Soft Implant: Biomechanical Analysis

This study was to evaluate the effect of stress on the intervertebral disc and facet joint after implantation of device for intervertebral assisted motion (DIAM). Nine fresh human lumbar (L1-L5) cadavers were studied. The stress on L3-4, adjacent intervertebral disc and facet joints was measured in four groups. The cadavers in Group 1 were measured without special treatment; the lumbar discecto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of spinal disorders & techniques

دوره 24 7  شماره 

صفحات  -

تاریخ انتشار 2011