Analysis of procedural effects of percutaneous edge-to-edge mitral valve repair by 2D and 3D echocardiography.

نویسندگان

  • Ertunc Altiok
  • Sandra Hamada
  • Kathrin Brehmer
  • Kathrin Kuhr
  • Sebastian Reith
  • Michael Becker
  • Jörg Schröder
  • Mohammad Almalla
  • Walter Lehmacher
  • Nikolaus Marx
  • Rainer Hoffmann
چکیده

BACKGROUND Analysis of procedural effects in patients undergoing percutaneous mitral valve repair (PMVR) using the edge-to-edge technique is complex, and common methods to define mitral regurgitation severity based on 2-dimensional (2D) echocardiography are not validated for postprocedural double-orifice mitral valve. This study used 3D transesophageal echocardiography (TEE) to determine the functional and morphological effects of PMVR. METHODS AND RESULTS In 39 high-risk surgical patients with moderate to severe functional mitral valve regurgitation, 3D TEE with and without color Doppler as well as 2D transthoracic and TEE was performed before and after PMVR (MitraClip device). Mitral valve regurgitant volume by color Doppler 3D TEE was determined as the product of vena contracta areas defined by direct planimetry and velocity time integral using continuous-wave Doppler. Regurgitant volume was reduced from 84.1±38.3 mL preintervention to 35.6±25.6 mL postintervention. Patients in whom vena contracta area could be reduced >50% had a smaller preprocedural mitral annulus area compared with patients with ≤50% reduction (11.9±3.9 versus 16.1±8.5 cm(2), respectively; P=0.036) and tended to have a smaller mitral annulus circumference (13.0±2.0 versus 14.8±4.1 cm, respectively; P=0.112). At 6 months follow-up, left atrial and left ventricular end-diastolic volumes were significantly more reduced in patients in whom regurgitant vena contracta area was reduced by >50% compared with those with less reduction (-11.4±5.2 versus -4.8±7.7%; P=0.005, and -11.0±7.2 versus -4.5±9.3%; P=0.028). The maximum diastolic mitral valve area decreased from 6.0±2.0 to 2.9±0.9 cm(2) (P<0.0001). CONCLUSIONS Three dimensional TEE demonstrates significant reduction of regurgitant volume after PMVR. The unique visualization of the mitral valve by 3D TEE allows improved understanding of the morphological and functional changes induced by PMVR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical revision after percutaneous mitral valve repair by edge-to-edge device: when the strategy fails in the highest risk surgical population.

OBJECTIVES Percutaneous edge-to-edge devices for non-surgical repair of mitral valve regurgitation are under clinical evaluation in high-risk patients deemed not suitable for conventional surgery. To address guidelines for initial therapy decision, we here report on 13 cases of surgery after failed percutaneous edge-to-edge mitral valve repair or attempted repair, and discuss methodology and pr...

متن کامل

Role of echocardiography in percutaneous mitral valve interventions.

Intraprocedural imaging continues to evolve in parallel with advances in percutaneous mitral valve interventions. This didactic review uses several illustrations and rich intraprocedural videos to further describe and demonstrate the role of the most up-to-date echocardiographic and advanced imaging technologies in the patient selection and intraprocedural guidance of percutaneous mitral valve ...

متن کامل

The predictive value of conventional surgical risk scores for periprocedural mortality in percutaneous mitral valve repair

BACKGROUND Surgical risk scores are used to identify high-risk patients for surgical mitral valve repair. There is no scoring system to estimate the mortality risk for patients undergoing percutaneous treatment. The aim of this analysis is to evaluate the predictive value of the EuroSCOREs and the Society of Thoracic Surgeons Predicted Risk of Mortality Score (STS) for periprocedural mortality ...

متن کامل

Percutaneous edge-to-edge mitral valve repair escorted by left atrial intracardiac echocardiography (ICE).

Andreas Henning, Iris I. Mueller, Karin Mueller, Christine Zuern, Tobias Walker, Meinrad Echocardiography (ICE) Percutaneous Edge-to-Edge Mitral Valve Repair Escorted by Left Atrial Intracardiac Print ISSN: 0009-7322. Online ISSN: 1524-4539 Copyright © 2014 American Heart Association, Inc. All rights reserved. is published by the American Heart Association, 7272 Greenville Avenue, Dallas, TX 75...

متن کامل

Finite element analysis for edge-to-edge technique to treat post-mitral valve repair systolic anterior motion.

Systolic anterior motion of the mitral valve is an uncommon complication of mitral valve repair, which requires immediate supplementary surgical action. Edge-to-edge suture is considered as an effective technique to treat post-mitral valve repair systolic anterior motion by clinical researchers. However, the fundamentals and quantitative analysis are vacant to validate the effectiveness of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 5 6  شماره 

صفحات  -

تاریخ انتشار 2012