Direct coronary artery perfusion from the left ventricle.
نویسندگان
چکیده
OBJECTIVES Trends in coronary bypass surgery require less invasive techniques and more conduits. We investigated the ability of direct coronary perfusion from the left ventricle to support regional and global cardiac function. METHODS A conduit was established between the left ventricle and left anterior descending coronary artery (n = 6) with an interposed Starling resistor that allowed for graded regulation of backward flow. Changes of coronary flow, regional function in the territory of the left anterior descending coronary artery, and reactive hyperemia were studied. In 3 separate dogs, functional tolerance to increased heart rate was tested. In another 3 dogs, left ventricle-left anterior descending and left ventricle-left circumflex coronary artery conduits were established simultaneously (double conduit), and global function was tested. RESULTS Without flow regulation, flow through the left ventricle-left anterior descending conduit exhibited high peaking (102 +/- 35 mL/min), midsystolic forward flow, and large pandiastolic backward flow (peaking at -47 +/- 22 mL/min). Mean coronary flow and regional function were maintained at 46.0% +/- 7.1% (35.8%-54.2%) and 45.3% +/- 29.1% (-1.8%-74.2%) of their respective normal values. When the Starling resistor was used to regulate backward flow, these values increased to 70.8% +/- 12.5% (56.8%-90.4%) and 70.2% +/- 27.8% (23.6%-107.7%), respectively. Coronary and functional reserve with a left ventricle-left anterior descending conduit were not observed. With the double conduit, global ventricular contractility indexed by end-systolic pressure-volume relation averaged 46% +/- 35% of its normal value. CONCLUSIONS A left ventricle-coronary artery conduit supplied approximately 45% of normal blood flow and regional function, and both were improved by regulation of backward flow. Therefore, a conduit from the left ventricle to an epicardial vessel could serve as a rapidly deployable means of revascularizing totally occluded coronary vessels for which suitable natural conduits are not available.
منابع مشابه
Detection of Cardiac Artery Disease by Using the DCAD (b) Module
Introduction: In patients with cardiac artery disease, a myocardial perfusion scan, which is a non-invasive method, is utilized. This study is conducted to develop an advantageous software applicable to quantitative myocardial SPECT perfusion. Material and Methods: Each cross-section of the left ventricle was segmented by applying a fuzzy clustering method. After obtaining the myocardial skelet...
متن کاملPrediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملAnomalous origin of left coronary artery from the left ventricle.
A 54-year-old asymptomatic woman (M.H.S.), was referred to the Hospital das Clínicas da Universidade Federal de Minas Gerais (HC/UFMG) cardiology service for routine cardiological evaluation in 2006. The physical examination and basal ECG were normal. Exercise stress testing showed unspecific ST segment alteration, and technetium scintigraphy was normal. One year later, repeat examination showe...
متن کاملChest Pain, Something is Not Right…Or Left.
A 46-year-old female was referred for evaluation of central chest pain unrelated to exertion. She was known to have diabetes mellitus, hypertension, and dyslipidaemia. Physical examination, routine blood investigations, electrocardiogram and chest radiograph were unremarkable. Stress myocardial perfusion imaging demonstrated normal perfusion of the left ventricle (LV) with no ischaemia detected...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of thoracic and cardiovascular surgery
دوره 121 2 شماره
صفحات -
تاریخ انتشار 2001