Method development validation for corticoids in animal feed samples by liquid chromatography using a monolithic column.

نویسندگان

  • Roberto Muñiz-Valencia
  • Raquel Gonzalo-Lumbreras
  • Ana Santos-Montes
  • Roberto Izquierdo-Hornillos
چکیده

A LC method for corticosteroids (CC) determination in poultry feed using a Chromolith column and UV detection has been developed and validated. The method development involved the optimization of different hydro-organic mobile phases using methanol or ACN as organic modifiers, flow rate, and temperature. The optimum separation was achieved at 40 degrees C using ACN/water (21:79 v/v) as mobile phase and 3 mL/min flow rate, allowing the separation to baseline of four out of seven CC in about 10 min. Prior to LC, a sample preparation procedure previously assayed for anabolics was used. It includes a leaching process, saponification of the esters from fatty acids, and SPE. Method validation was carried out according to the EU criteria established for quantitative screening methods. The extraction efficiencies, decision limits (CCalpha), and detection capabilities (CCbeta) for these compounds were in the ranges of 86-92%, 27-36 microg/kg, and 33-43 microg/kg, respectively. The repeatability and the within-laboratory reproducibility at 1, 1.5, and 2 CCbeta concentration levels were smaller than 9.0, 5.0, and 4.2% and 9.4, 6.4, and 4.9%, respectively. The CV values of the robustness test were less than 3.8% and the accuracy was in the range of 98-103%. The proposed method was applied to other feed with satisfactory results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A liquid chromatography method using a monolithic column for the determination of corticoids in animal feed and animal feeding water.

An HPLC-DAD method for determining corticoids in calf feed and in animal feeding water samples using a monolithic column has been developed and validated. The method optimization included the study of binary mobile phases of water and acetonitrile. The optimum separation was achieved at 40 degrees C, with acetonitrile:H(2)O 29:71 v/v used as mobile phase and a 3 ml/min flow-rate, which resulted...

متن کامل

Liquid chromatographic method development for anabolic androgenic steroids using a monolithic column Application to animal feed samples.

An isocratic HPLC method for the determination with screening purposes of anabolic androgenic steroids (AASs: fluoxymesterone, boldenone, nortestosterone, metandrostenolone, norethindrone, methyltestosterone and bolasterone), used as growth promoting agents, in finishing pig feed samples has been developed and validated. The separation was achieved by using a reversed-phase Chromolith RP-18e co...

متن کامل

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

Development of an immunoaffinity chromatography and LC-MS/MS method for the determination of 6 zearalenones in animal feed

A novel and simple method for detecting 6 zearalenones in animal feed using liquid chromatography coupled with triple quadrupole mass spectrometry (LC-MS/MS) and immunoaffinity columns (IAC) was developed. The chromatographic peaks of the 6 zearalenones were successfully identified by comparing their retention times and mass spectrum with reference standards. The mobile phase was composed of mo...

متن کامل

Development of Homogeneous Liquid-Liquid Extraction in Combination with Dispersive Liquid-Liquid Microextraction Based on Deep Eutectic Solvents for the Extraction and Assessment of Phytosterols in Animal Cream Samples using Gas Chromatography Equipp

Background and Objectives: Food quality and safety control is an important part of the public health assessment of food adulteration has been a key issue in recent years. Cream is a product containing milk fat and is one of the most expensive and widely consumed edible fats, which is often targeted for cheating by mixing various vegetable oils with natural milk fats. A way to detect this type o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of separation science

دوره 30 17  شماره 

صفحات  -

تاریخ انتشار 2007