Importance of powder residence time for the aerosol delivery performance of a commercial dry powder inhaler Aerolizer(®).

نویسندگان

  • Liqun Jiang
  • Yue Tang
  • Hongjiu Zhang
  • Xifeng Lu
  • Xijing Chen
  • Jiabi Zhu
چکیده

BACKGROUND The performance of dry powder aerosol delivery systems depends not only on the powder formulation but also on the dry powder inhalers (DPIs). Effects of turbulence, grid, mouthpiece, inlet size, air flow, and capsule on the DPIs performance have been investigated previously. Considering powder dispersion in DPIs is a time-dependent process, the powder residence time in DPIs is supposed to have a great impact on DPIs efficiency. This study sought to investigate the effect of powder residence time on the performance of a commercial DPI Aerolizer(®). METHODS A standard Aerolizer(®) (SD) and five modified devices (MD1, MD2, MD3, MD4, and MD5) were employed for this research. Computational fluid dynamics analysis was used to calculate the flow field and the powder residence time in these devices. Recombinant human interleukin-2 inhalation powders and a twin impinger were used for the deposition experiment. RESULTS The powder mean residence time in the secondary atomization zone of the devices was increased from 0 ms for SD to 0.33, 0.96, 1.42, 1.76, and 2.14 ms for MD1, MD2, MD3, MD4, and MD5, respectively. At a flow rate of 60 L/min, with an increase in the powder residence time in these devices, a significant gradual and increasing trend in the powder respirable fraction was observed from 29.1%± 1.1% (MD1) to 32.6% ± 2.2% (MD2), 37.1% ± 1.1% (MD3), and 43.7% ± 2.1% (MD4). There was no significant difference in the powder respirable fraction between SD and MD1 or between MD4 and MD5. CONCLUSIONS Within a certain range, increasing the powder residence time could improve the performance of Aerolizer(®) by increasing the powder-air interaction time (the main reason) and increasing the powder-device compaction (the secondary reason). Combination of high turbulence level and sufficient powder residence time could further improve the device performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dry powder inhaler device influence on carrier particle performance.

Dry powder inhalers (DPIs) are distinguished from one another by their unique device geometries, reflecting their distinct drug detachment mechanisms, which can be broadly classified into either aerodynamic or mechanical-based detachment forces. Accordingly, powder particles experience different aerodynamic and mechanical forces depending on the inhaler. However, the influence of carrier partic...

متن کامل

Antibacterial loaded Spray Dried Chitosan Polyelectrolyte Complexes as Dry Powder Aerosol for the Treatment of Lung Infections

Inhalation delivery of aerosolized antibacterials is preferred over conventional methods of delivery for targeting lung infection. The present study is concerned with the development and characterization of a novel, spray dried, aerosolized, chitosan polyelectrolyte complex (PEC) based microparticles containing antibacterials for the treatment of lung infections.Chitosan polyelectrolyte complex...

متن کامل

Antibacterial loaded Spray Dried Chitosan Polyelectrolyte Complexes as Dry Powder Aerosol for the Treatment of Lung Infections

Inhalation delivery of aerosolized antibacterials is preferred over conventional methods of delivery for targeting lung infection. The present study is concerned with the development and characterization of a novel, spray dried, aerosolized, chitosan polyelectrolyte complex (PEC) based microparticles containing antibacterials for the treatment of lung infections.Chitosan polyelectrolyte complex...

متن کامل

Effect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 1: Grid structure and mouthpiece length.

This study investigates (1) the effect of modifying the design of a dry powder inhaler on the device performance, and (2) which design features significantly contribute to overall inhaler performance. Computational Fluid Dynamics (CFD) analysis was performed to determine how the flowfield generated in an Aerolizer at 60 l min(-1) varied when the inhaler grid and mouthpiece were modified. The co...

متن کامل

Metered-dose inhalers and dry powder inhalers in aerosol therapy.

Inhaled drug delivery is an important part of the armamentarium of clinicians caring for patients with pulmonary disease. An increasing variety of metered-dose inhalers and dry powder inhalers are becoming available. This has been driven by the development of new formulations and the impending ban on chlorofluorocarbon propellants. The result is a proliferation of devices, resulting in a confus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of aerosol medicine and pulmonary drug delivery

دوره 25 5  شماره 

صفحات  -

تاریخ انتشار 2012