Legionella anisa, a possible indicator of water contamination by Legionella pneumophila.

نویسندگان

  • Nathalie van der Mee-Marquet
  • Anne-Sophie Domelier
  • Laurence Arnault
  • Daniel Bloc
  • Patrice Laudat
  • Philippe Hartemann
  • Roland Quentin
چکیده

Legionella anisa is one of the most frequent species of Legionella other than Legionella pneumophila in the environment and may be hospital acquired in rare cases. We found that L. anisa may mask water contamination by L. pneumophila, suggesting that there is a risk of L. pneumophila infection in immunocompromised patients if water is found to be contaminated with Legionella species other than L. pneumophila.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospective monitoring study: isolating Legionella pneumophila in a hospital water system located in the obstetrics and gynecology ward after eradication of Legionella anisa and reconstruction of shower units.

We previously reported on the sporadic contamination by Legionella anisa of shower units and sink taps at Ryukyu University Hospital. Starting in July 2003, the neonatal area underwent an 8-month reconstruction, and in March 2005, the boiler system was replaced. We therefore examined shower water and tap water for the presence of Legionella just after replacement of the boiler system. In 3 of t...

متن کامل

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

فراوانی لژیونلا پنوموفیلا در شیر آب سرد و گرم و مخزن آب انکوباتورهای بخش نوزادان بیمارستانهای گیلان

Background and purpose: Nosocomial outbreaks of legionnaires’ diseases are usually related to contamination of water sources. This survey investigated the frequency of mip gene in cold and warm water taps and water containers of infant incubators containing legionella pneumophila in hospitals of Guilan province, Iran. Materials and methods: This cross-sectional study used 140 samples. They wer...

متن کامل

First Case of Legionnaire's Disease Caused by Legionella anisa in Spain and the Limitations on the Diagnosis of Legionella non-pneumophila Infections

Legionnaires' disease is a severe form of pneumonia, with worldwide relevance, caused by Legionella spp. Approximately 90% of all cases of legionellosis are caused by Legionella pneumophila, but other species can also be responsible for this infection. These bacteria are transmitted by inhalation of aerosols or aspiration of contaminated water. In Spain, environmental studies have demonstrated ...

متن کامل

Legionella anisa and hospital water systems.

V.L. Yu (*) · J.E. Stout VA Medical Center, Infections Disease Section, 111 E-U, University Drive C, Pittsburgh, PA 15240, USA Tel. 1-412-688-6643; Fax 1-412-688-6950 e-mail: [email protected] To the Editor, Concerning the article by Yamamoto et al. entitled “Isolation of Legionella anisa from multiple sites of a hospital water distribution system”; published recently in the Journal of Infection and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 44 1  شماره 

صفحات  -

تاریخ انتشار 2006