An optomechanical model eye for ophthalmological refractive studies.

نویسندگان

  • Ashkan Arianpour
  • Eric J Tremblay
  • Igor Stamenov
  • Joseph E Ford
  • David J Schanzlin
  • Yuhwa Lo
چکیده

PURPOSE To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. METHODS An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. RESULTS Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. CONCLUSIONS A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser eye surgery for refractive errors.

Several laser and non-laser refractive surgical procedures have been used to modify the shape of the cornea and correct myopia, hyperopia, astigmatism, and presbyopia. Introduction of the excimer laser to reshape the cornea has resulted in remarkable developments in the correction of these refractive errors. Combined with other advanced ophthalmological instruments, laser refractive eye surgery...

متن کامل

Study of Optical Models Regarding the Human Eye

Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...

متن کامل

To avoid post-operative refractive error in cataract surgery.

One of the greatest issues facing the cataract surgeon today is accurate prediction of post-operative refractive error. With use of intraoperative autorefractometry (IOAR), such errors can be detected and post-operative refractive errors avoided. An 83-year-old woman was admitted for right eye phacoemulsification, with aimed at -1.78D with Sanders/Retzlaff/Kraff/T (SRK/T) formula implantation u...

متن کامل

Ophthalmological disorders in rural areas of Crete: a geospatial analysis.

INTRODUCTION Estimation of the prevalence of vision impairment in a population can be performed using epidemiological research. The purpose of this study was to measure, using spatial statistics, the prevalence of ophthalmologic disease identified at visits of the Mobile Ophthalmologic Unit (MOU) of the Vardinogiannion Eye Institute of Crete (VEIC) to villages in Crete. The study also aimed to ...

متن کامل

Long-Term Outcomes of Radial Keratotomy, Laser In Situ Keratomileusis, and Astigmatic Keratotomy Performed Consecutively over a Period of 21 Years

UNLABELLED Purpose. To describe a case of 3 refractive procedures performed in one eye over 2 decades. Methods. CASE REPORT Results. A 41-year-old patient presented for refractive surgery evaluation. His ocular history includes bilateral radial keratotomy performed 21 years ago for moderate myopia: spherical equivalence of -4.25 D bilaterally. Postoperative uncorrected visual acuity (UCVA) wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 29 2  شماره 

صفحات  -

تاریخ انتشار 2013