[Diagnostic capability of PULSAR, FDT y HRT-II in glaucoma suspects].
نویسندگان
چکیده
PURPOSE To determine the diagnostic capability of PULSAR-T30W, FDT-Threshold-N30 and HRT-II in glaucoma suspects. METHODS Forty-seven eyes from 47 referred glaucoma suspects (GS) were examined twice with each technique. Cases with TOP-WW-MD>6dB were excluded. Results were compared with those of 70 eyes from 70 normal controls (C). RESULTS Mean MD value using TOP-WW in the GS group (0.96dB. sd=1.7) was not significantly different from C (0.8dB. sd=1.77) (p>0.05). Disc area in GS group (2.12 mm(2). sd=0.34) was significantly greater than in C (1.97 mm2. sd=0.45) (p<0.01). For 95.7% specificity, PULSAR-sLV showed the highest sensitivity of 30.9% in individual examinations. The highest reproducible sensitivity in the two examinations was obtained using HRT-II maximum contour elevation (23.4%) and reference height (23.4%), and was 14.9% for various indices after correcting for the influence of disc area (cup area, cup/disc area ratio, maximum contour depression and mean RNFL thickness). Reproducible sensitivity of the perimetric indices was: PULSAR-MD=8.5%, PULSAR-sLV=17%, FDT-MD=6.4%, FDT-PSD=4.3%. The association of perimetric and HRT-II indices achieved high sensitivity but low diagnostic reproducibility. CONCLUSIONS The most effective indices were maximum contour elevation, reference height and PULSAR-sLV, although the inclusion of the optic nerve head assessment in the selection of the GS sample may have favored the HRT-II results.
منابع مشابه
Correlation between frequency doubling technology perimetry and scanning laser polarimetry in glaucoma suspects and glaucomatous eyes.
The aim of this study was to determine the relationship between the frequency doubling technology (FDT) screening algorithm and parapapillary retinal nerve fiber layer (RNFL) thickness in the eyes of glaucoma suspects and patients with open angle glaucoma. FDT C20-1 screening program and a scanning laser polarimetry (SLP) system (GDx-NFA) was used to assess 53 glaucomatous eyes, 53 glaucoma sus...
متن کامل[Evaluation of four new discriminant functions for HRT II in glaucoma diagnosis].
PURPOSE To assess the diagnostic usefulness of four linear discriminant functions for Heidelberg retina tomograph (HRT) II obtained in our population. METHODS 450 eyes of 450 patients were studied. Eyes were classified as those of healthy subjects (101), those with ocular hypertension (126), those suspected to have glaucoma (121) or those with glaucoma (103). Intraocular pressure, optic nerve...
متن کاملEvaluation of the significance of some diagnostic parameters in making an early diagnose of primary open-angle glaucoma
BACKGROUND The aim of this study was to evaluate diagnostic parameters and analysis of their advantages and limitations in early diagnostics of primary open-angle glaucoma (POAG). Cup/disc ratio (C/D), nerve fiber index (NFI) and mean deviation of retinal sensitivity (MD) were considered. MATERIAL/METHODS Fifty primary open-angle glaucoma patients (95 eyes), 67 primary open-angle glaucoma sus...
متن کاملComparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes
BACKGROUND Perimetry is indispensable for the clinical management of glaucoma suspects. Our goal is to compare the performance of standard automated perimetry (SAP) and Matrix frequency-doubling technology (FDT) perimetry in monitoring the development of visual field (VF) defects in glaucoma suspect eyes. METHODS Longitudinal data of paired SAP and FDT from 221 eyes of 155 glaucoma suspects e...
متن کاملScreening tests for detecting open-angle glaucoma: systematic review and meta-analysis.
PURPOSE To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG). METHODS Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archivos de la Sociedad Espanola de Oftalmologia
دوره 82 7 شماره
صفحات -
تاریخ انتشار 2007