Determination of corticosterone and 17-hydroxycorticosterone in plasma and urine samples by sweeping techniques using micellar electrokinetic chromatography.

نویسندگان

  • Mei-Chuan Chen
  • Shiu-Huey Chou
  • Cheng-Huang Lin
چکیده

The analysis of corticosterone in mouse blood serum (metabolic-stress experiment) and 17-hydroxycorticosterone in human urine (exercise-stress experiment) samples by means of capillary electrophoresis/UV absorbance in conjunction with online sample concentration techniques is described. The use of normal MEKC had an analyte detection limit of 7 microg/ml (S/N=3); whereas when online sample concentration methods, including sweeping-micellar electrokinetic chromatography (Sweeping-MEKC) and cation-selective exhaustive injection-sweep-micellar electrokinetic chromatography (CSEI-sweep-MEKC) were used, the detection limits could be improved to 3 and 5 ng/ml, respectively. In the analysis of actual samples from animal metabolic-stress experiments (39 mouse), chronically stressed animals showed a higher level (552+/-152 ng/ml) and acute stressed animals showed an intermediate level (375+/-105 ng/ml). In comparison, normal animals show a lower concentration level of corticosterone (153+/-109 ng/ml). In addition, based on a human exercise-stress experiment (seven volunteers), the acute stressed humans (after exercise, 800 m of running) show a higher concentration of 17-hydroxycorticosterone (113+/-55 ng/ml for males; 128+/-25 for females) and the non-stressed humans (before exercise) show a lower concentration (63+/-37 ng/ml for male; 60+/-20 for female), respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methanol plug assisted sweeping-micellar electrokinetic chromatography for the determination of dopamine in urine by violet light emitting diode-induced fluorescence detection.

The use and limitations of a methanol plug assisted sweeping-micellar electrokinetic chromatography (sweeping-MEKC) method is described. Using naphthalene-2,3-dicarboxaldehyde (NDA)-labeled dopamine as a model compound, this new method was also used in the determination of dopamine in actual urine samples. An inexpensive violet light emitting diode (LED) was used for the light source, because t...

متن کامل

Determination of lysergic acid diethylamide (LSD) by application of online 77 K fluorescence spectroscopy and a sweeping technique in micellar electrokinetic chromatography.

The principal advantage of the use of Shopl'skii effect (low temperature spectrum) is that spectral sharpening occurs both in absorption and emission. However, thus far using the technique of capillary electrophoresis/low temperature fluorescence spectroscopy (CE/LTFS) either at 77 or 4.2 K remains difficult to obtain an on-line spectrum, if the analyte is present at low concentration. This pap...

متن کامل

Using sweeping micellar electrokinetic chromatography to analyze Delta9-tetrahydrocannabinol and its major metabolites.

We have applied sweeping micellar electrokinetic chromatography (sweeping-MEKC) to the simultaneous determination of Delta(9)-tetrahydrocannabinol (THC) and its major metabolites, 11-hydroxy-Delta(9)-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH). We monitored the effects of several of the sweeping-MEKC parameters, including the proportion of organic...

متن کامل

Optimization of the separation of lysergic acid diethylamide in urine by a sweeping technique using micellar electrokinetic chromatography.

The separation and on-line concentrations of lysergic acid diethylamide (LSD), iso-lysergic acid diethylamide (iso-LSD) and lysergic acid N,N-methylpropylamide (LAMPA) in human urine were investigated by capillary electrophoresis-fluorescence spectroscopy using sodium dodecyl sulfate (SDS) as an anionic surfactant. A number of parameters such as buffer pH, SDS concentration, Brij-30 concentrati...

متن کامل

Sweeping technique combined with micellar electrokinetic chromatography for the simultaneous determination of flunitrazepam and its major metabolites.

A sweeping technique, in conjunction with micellar electrokinetic chromatography, for the simultaneous determination of flunitrazepam and its major metabolites, 7-aminoflunitrazepam and N-desmethylflunitrazepam, is described. The optimized conditions for the sweeping and separation were a pH 9.5 buffer, 25mM borate, 50mM cetyltrimethylammonium bromide, 30% MeOH (v/v), and a 151-mm injection len...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

دوره 801 2  شماره 

صفحات  -

تاریخ انتشار 2004