Impact of atlas-CT-based bone anatomy compensation on MR-based attenuation correction for brain PET imaging in a time-of-flight PET/MRI system: A direct comparison to a patient-CT-based approach.

نویسندگان

  • Jaewon Yang
  • Yiqiang Jian
  • Michel Tohme
  • Spencer Behr
  • Daniel Vigneron
  • Sharmila Majumdar
  • Youngho Seo
چکیده

University of California, San Francisco, USA An atlas-CT-based bone-anatomy compensation for MR-based attenuation correction (MRAC) in brain PET/MRI imaging is a current standard. However, the impact of an anatomical difference has not been clinically evaluated. Thus, we aim to evaluate the impact of the anatomical dissimilarity on MRAC. Whole-body FDG-PET/CT followed by PET/MRI were performed for twelve patients in an integrated TOF PET/MRI system. The MRAC utilized an atlas-CT (MRAC-atlas) as well as a patient-specific-CT (MRAC patient) to produce AC maps (pseudo-CT). Instead of using atlas-CT, the MRAC-patient approach derived pseudo-CT from patient-specific-CT aligned to MR. For quantitative evaluation, CTAC was considered as gold standard for AC, and PET mean activity concentration values were measured and compared in eight 10 ml volumes-of-interest (VOI). PET activity concentration with MRAC, compared to CTAC, were systematically underestimated on average by 0.63±0.34 kBq/ml (4.0±2.2%) and 0.22±0.21 kBq/ml (1.4±1.5%) for the MRAC-atlas and the MRAC-patient, respectively: using the MRAC atlas, the error was increased to 0.41±0.25 kBq/ml (2.6±1.8%) on average (p≈0). However, the error increase was patient-dependent (highest: 5.7% vs. lowest: 0.3%) and VOI dependent (highest 3.1% vs. lowest: 1.9%). For the first time, the atlas-CT based MRAC was compared to the patient-specific-CT-based MRAC for brain PET imaging in an integrated TOF PET/ MRI system. Overall, the MRAC-atlas achieves quantification accuracy similar to CTAC with a small but measurable difference of 5% in values, which is 2.6% higher than the error of the MRAC-patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

Estimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom

One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...

متن کامل

MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration.

UNLABELLED For quantitative PET information, correction of tissue photon attenuation is mandatory. Generally in conventional PET, the attenuation map is obtained from a transmission scan, which uses a rotating radionuclide source, or from the CT scan in a combined PET/CT scanner. In the case of PET/MRI scanners currently under development, insufficient space for the rotating source exists; the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • EJNMMI physics

دوره 2 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2015