Parametric [11C]flumazenil images.

نویسندگان

  • Ursula M H Klumpers
  • Ronald Boellaard
  • Dick J Veltman
  • Reina W Kloet
  • Witte J G Hoogendijk
  • Adriaan A Lammertsma
چکیده

OBJECTIVE This [11C]flumazenil (FMZ) study evaluates the performance of various parametric analysis methods and their ability to detect statistically significant group differences. METHODS Dynamic 60-min FMZ scans were performed in eight healthy and nine individuals with major depressive disorder. Parametric volume of distribution (VT) images were generated using a basis function method (BFM) implementation of the single tissue compartment model (1T) and Logan plot analysis, both with a metabolite-corrected arterial plasma input function. Parametric binding potential (BP ND) images were generated using multilinear reference tissue methods (MRTM0-4), reference Logan and receptor parametric mapping (RPM1-2), with pons as a reference region. Standardized uptake value (SUV) and SUV ratio-to-pons (SUVr) images were calculated over the time interval 30-40 and 20-60 min postinjection. The resulting VT, BP ND, SUV and SUVr values were compared with nonlinear regression values, using both the 1T model and the simplified reference tissue model. Statistical parametric mapping (SPM5) was used to detect group differences, with an emphasis on the bilateral parahippocampal gyri. RESULTS BFM was more accurate than Logan, but showed more variability. Both RPM methods and MRTM2 showed the best average correlation with the simplified reference tissue model. In using SPM, SUV and SUVr images provided the best contrast between groups in the parahippocampal gyri, but provided large underestimation and overestimation in quantitative comparisons. BFM and RPM methods allowed for the determination of perfusion effects. CONCLUSION Parametric Logan VT, MRTM2 and RPM1-2 BP ND methods allow the best quantitative comparison of FMZ binding between groups and show good discriminating performance in SPM analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[11C]flumazenil PET: activity images versus parametric images for the detection of neocortical epileptic foci.

UNLABELLED [11C]flumazenil (FMZ) imaged with PET allows the computation of parametric images of both tracer influx (K1) and volume of distribution (VD). The VD images, which allow visualization of a quantitative measure of benzodiazepine receptor binding, are reported to have high sensitivity and specificity for the delineation of epileptic foci. However, the clinical feasibility of this method...

متن کامل

Diagnostic Performance of Positron Emission Tomography for the Presurgical Evaluation of Patients with Non-lesional Intractable Partial Epilepsy: Comparison among 18F-FDG, 11C-Flumazenil, and 11C-Flumazenil Binding Potential Imaging Using Statistical Imaging Analysis.

To compare the diagnostic performance of 18F-FDG PET, 11C-FMZ PET, and 11C-FMZ BP imaging for the evaluation of patients with intractable partial epilepsy whose MRI findings are normal by using statistical imaging analysis. Ten patients underwent comprehensive presurgical evaluation, including PET studies, to assess the epileptic foci. The extent of cortical resection was based on the results o...

متن کامل

PET Imaging of 18F-FDG, 11C-methionine, 11C-flumazenil, and 11C-4DST in Progressive Multifocal Leukoencephalopathy

The use of positron emission tomography (PET) imaging in progressive multifocal leukoencephalopathy (PML) has rarely been reported. We herein report a set of PET images in a 63-year-old patient with PML. In PML lesions, the uptake of 18F-fluorodeoxyglucose, 11C-methionine, 11C-flumazenil, and [methyl-11C]4'-thiothymidine was decreased, increased, decreased, and unchanged, respectively. These re...

متن کامل

[11C]Flumazenil brain uptake is influenced by the blood-brain barrier efflux transporter P-glycoprotein

BACKGROUND [11C]Flumazenil and positron emission tomography (PET) are used clinically to assess gamma-aminobutyric acid (GABA)-ergic function and to localize epileptic foci prior to resective surgery. Enhanced P-glycoprotein (P-gp) activity has been reported in epilepsy and this may confound interpretation of clinical scans if [11C]flumazenil is a P-gp substrate. The purpose of this study was t...

متن کامل

Intrasubject correlation between static scan and distribution volume images for [11C]flumazenil PET.

Accumulation of [11C]flumazenil (FMZ) reflects central nervous system benzodiazepine receptor (BZR). We searched for the optimal time for a static PET scan with FMZ as semi-quantitative imaging of BZR distribution. In 10 normal subjects, a dynamic series of decay-corrected PET scans was performed for 60 minutes, and the arterial blood was sampled during the scan to measure radioactivity and lab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nuclear medicine communications

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 2012