Effect of different orientations of screw fixation for radial head fractures: a biomechanical comparison

نویسندگان

  • Xuchao Shi
  • Tianlong Pan
  • Dengying Wu
  • Ningyu Cai
  • Rong Chen
  • Bin Li
  • Rui Zhang
  • Chengwei Zhou
  • Jun Pan
چکیده

BACKGROUND Screw fixation is a common method used for the treatment of Mason type II radial head fractures. The purpose of our study was to evaluate the mechanical properties of three different screw orientations used for fixation of Mason type II radial head fractures. METHODS We sawed 24 medium-frequency fourth-generation Synbone radial bones to simulate unstable radial head fractures, which we then fixed with three different screw orientations. Implants were tested under axial load by the tension-torsion composite test system. If the implant-radial constructs did not fail after the axial load test, an axial failure load was added to the remaining constructs. RESULTS The stiffness of the divergent group was the highest of the three orientations, and this group had statistically significant difference from the other two groups (p < 0.05). However, there was no statistically significant difference between the convergence group and the parallel group (p > 0.05). When the displacement reached 2 mm, the load of the divergent screw was still larger than the other two groups (p < 0.05). CONCLUSIONS The divergent screw orientation was the most stable and had the greatest control of Mason type II fractures of these three groups. Therefore, it can be better applied in clinical settings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of three different fixation constructs for radial neck fractures: a biomechanical study

BACKGROUND Fixation of radial neck fractures can be achieved with a plate and screw construct or with two screws. This study evaluated the biomechanical properties of three different fixation methods following radial neck fractures. METHODS Twenty-four fourth-generation composite radii were sawed to simulate an unstable radial neck fracture. They were then instrumented with a plate and screw ...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

The Best Option in Treatment of Modified Mason Type III Radial Head Fractures: Open Reduction and Internal Fixation Versus Radial Head Excision

Background: Radial head fractures commonly occur during elbow traumas. Among those, treatment of Mason type IIIfractures is still under controversy. Common treatment methods for these fractures include open reduction and internalfixation (ORIF) as well as radial head excision. In this study, we compared long-term outcomes of both methods intreatment of patients with Mason type III fractures of ...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Comparison of crossed screw versus plate fixation for radial neck fractures.

BACKGROUND Fixation of radial neck fractures can be achieved with a plate and screw construct or, in absence of comminution, with two obliquely-oriented screws. This study investigated the mechanical properties, specifically the stiffness and load to failure, of these two fixation strategies in a cadaver model. METHODS Ten matched-pair radii were removed from fresh cadaver arms. A transverse ...