Effects of time and temperature on 48 routine chemistry, haematology and coagulation analytes in whole blood samples.
نویسندگان
چکیده
Background Phlebotomy for the purpose of blood analysis is often performed at remote locations, and samples are usually temporarily stored before transport to a central laboratory for analysis. The circumstances during storage and shipment may not meet the necessary requirements. If analysed anyway, false results may be generated. We therefore examined the influence of precentrifugation time and temperature of the most frequently requested tests in whole blood. Methods Healthy volunteers donated blood in which 48 analytes were tested. Routine chemistry was performed in lithium heparin tubes, haematology in ethylenediaminetetraacetic acid tubes, coagulation in citrate tubes and glucose in sodium fluoride tubes. One tube was measured directly. The others were kept at different temperatures (4, 8, 20 or 30℃) and stored for 4, 6, 8 or 24 h before analysis. Additionally, some analytes were examined at 12, 16, 24 and 28℃. The mean percentage deviation was compared with different decision levels, including the total allowable error. Results When using the total allowable error as an acceptable limit, most of the investigated analytes remained stable. However, bicarbonate is unstable at almost all tested time-points and temperatures. Calcium, lactate dehydrogenase, potassium and sodium are particularly affected at low temperatures, while phosphate is mainly affected at and above room temperature after 8 h. Conclusion We established the influence of time and temperature on a broad range of analytes, which may be applied to set the limits in transportation and storage of whole blood samples.
منابع مشابه
Polymerization of Silica in Water-Effect of Ultrasonic Waves on Coagulation and Sedimentation
Polymerization rates of silica at various concentrations and pHs have been studied via nephelometry. The ability and potency of ultrasonic radiation on the coagulation process in aqueous samples with and without silica colloidal particles have been extensively investigated. Factors affecting the rate and filtration volume such as silica concentration, time of radiation, temperature, and fre...
متن کاملIn Vitro and in Vivo studies of the Effects of Cold Argon Plasma on Decreasing the Coagulation Time
Introduction Cold plasma is a self-sterilized, painless, and non-contact method in surgeries. These properties allow it to be applied to the living tissues and heat-sensitive parts. The aim of this study was to design a new cold plasma producer device and evaluate the effects of cold argon plasma on decreasing the coagulation time of blood drop in vitro and that of the injured liver blood in vi...
متن کاملDetermination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography
A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lu...
متن کاملNational survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China
INTRODUCTION To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. MATERIALS AND METHODS 479 Chinese clinical laboratories part...
متن کاملCan Unmanned Aerial Systems (Drones) Be Used for the Routine Transport of Chemistry, Hematology, and Coagulation Laboratory Specimens?
BACKGROUND Unmanned Aerial Systems (UAS or drones) could potentially be used for the routine transport of small goods such as diagnostic clinical laboratory specimens. To the best of our knowledge, there is no published study of the impact of UAS transportation on laboratory tests. METHODS Three paired samples were obtained from each one of 56 adult volunteers in a single phlebotomy event (33...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of clinical biochemistry
دوره 54 4 شماره
صفحات -
تاریخ انتشار 2017