BACKGROUND Reusable bedpans and urinals are frequently cleaned and decontaminated using washer-disinfectors (WDs) that may be located in the central processing department (CPD) or on the ward. The objective of this study was to determine how efficiently the WDs provided cleaning and to evaluate the ability of such WDs to kill Clostridium difficile spores. METHODS The cleaning efficacy of 2 bedpan/urinal WDs (1 in the ward [ward-WD] and 1 in the CPD [CPD-WD]) were evaluated using simulated-use testing that included an ultraviolet-visible marker (UVM) that is readily removed when exposed to liquid. In addition, a proprietary test object surgical instrument (TOSI) device was used to assess the efficacy of the WDs. Artificial test soil (ATS) and C. difficile spore removal and killing also were evaluated. The removal of approximately 10(6) C. difficile spores and subsequent killing of these spores was assessed using autoclaved stool and/or urine as the soil challenge. RESULTS Reusable stainless steel bedpans, plastic bedpans, and plastic urinals were assessed. Triplicate testing done on 3 separate days using TOSI devices, UVM, ATS, and stool and urine soils indicated that the ward-WD did not demonstrate adequate cleaning. It was determined that installation errors accounted for the inadequate cleaning. But the ward-WD did not adequately inactivate C. difficile spores even when the installation problems were corrected and the manufacturer-adjusted maximal thermal conditions were used. The CPD-WD was able not only to adequately clean the test devices of organic soil, but also to completely inactivate the 6 logs of C. difficile spores placed in sealed ampules inside the WD. CONCLUSION The results of this study indicate that user testing of the efficacy of WDs is critical to ensure appropriate functionality. The currently accepted thermal decontamination parameters for all bedpan WDs (ie, 80 degrees C for 1 minute) are not adequate to eliminate C. difficile spores from bedpans.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dutch surveys bedpan management (1990 & 2010): progress in correct use of washer disinfectors

Introduction / objectives In the Netherlands bedpans are regarded as semi-critical items unlike Spauldings scheme (1968), where bedpans are categorized as non-critical items. Washer-disinfectors (WD) were used incorrect for a long time. A survey in 1990 showed poor final cleaning and disinfection results. The Dutch Working Party Infection Prevention made guidelines for WD (1998), and in 2006 th...

متن کامل

Evaluation of cleaning and disinfection performance of automatic washer disinfectors machines in programs presenting different cycle times and temperatures.

Thermal washer-disinfectors represent a technology that brought about great advantages such as, establishment of protocols, standard operating procedures, reduction in occupational risk of a biological and environmental nature. The efficacy of the cleaning and disinfection obtained by automatic washer disinfectors machines in running programs with different times and temperatures determined by ...

متن کامل

An evaluation of washer-disinfectors (WD) and dishwashers (DW) effectiveness in terms of processing dental instruments.

PURPOSE The aim of this study is to consider the effectiveness of a small sample of dishwashers (DW) compared to washer-disinfectors (WD) for cleaning dental instruments prior to sterilisation. Processing instruments in the context of this article means cleaning and disinfecting the instruments. MATERIALS AND METHODS A number of tests were carried out on three domestic dishwashers and two ins...

متن کامل

Reprocessing of dental instruments in washer-disinfectors: does a representative test soil exist in dentistry?

BACKGROUND Reprocessing of medical devices, being classified as semi-critical B is recommended to be performed in a washer-disinfector. In order to estimate, whether the expected contaminants of the various medical disciplines can be effectively removed by this washer-disinfector, different so called "test soils" have been proposed to be tested as a marker of cleaning efficacy of the disinfecto...

متن کامل

Efficacy of hospital cleaning agents and germicides against epidemic Clostridium difficile strains.

OBJECTIVE To compare the effects of hospital cleaning agents and germicides on the survival of epidemic Clostridium difficile strains. METHODS We compared the activity of and effects of exposure to 5 cleaning agents and/or germicides (3 containing chlorine, 1 containing only detergent, and 1 containing hydrogen peroxide) on vegetative and spore forms of epidemic and non-epidemic C. difficile ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of infection control

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2008