Effect of percutaneous transthoracic lung biopsy on oxidative metabolism in sheep.

نویسندگان

  • Andreza A Silva
  • Danilo O L Ferreira
  • Bianca P Santarosa
  • Adriano Dias
  • Débora C Damasceno
  • Roberto C Gonçalves
چکیده

This study aimed to assess the effect of percutaneous transthoracic lung biopsy on the oxidative metabolism of sheep by measuring the oxidative stress markers of superoxide dismutase (SOD), total glutathione (GSH-t), peroxidase (GSH-Px) and thiobarbituric acid reactive substances (TBARS) in the red cells of these animals. Blood samples were collected from 20 clinically healthy sheep prior to, and 30 min after, percutaneous transthoracic lung biopsy. After biopsy, there was a significant decrease (p < 0.05) in SOD and GSH-Px activity, with no significant change (p ≥ 0.05) in GSH-t and TBARS concentrations. These results showed that percutaneous transthoracic lung biopsy did not significantly affect the oxidative metabolism of sheep 30 min after the procedure, which may be used widely in this species without causing serious tissue damage.  

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE

Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...

متن کامل

CT-guided percutaneous transthoracic needle biopsy of lung lesions – 2-year experience at the Institute of Radiology in Ljubljana

Background. In 1883, Leyden described percutaneous lung biopsy, but it was not until 1970s that image guided fine needle chest biopsy gained widespread acceptance. Haaga and Alfidi reported CT-guided thoracic biopsy in 1976. Currently, tissue sampling of a thoracic lesion is indicated when the diagnosis is not obtained by the endobronchial technique and when the cytological diagnosis will modif...

متن کامل

Current role of computed tomography-guided transthoracic needle biopsy of metastatic lung lesions.

AIM As part of the Catania symposium on lung metastasectomy we reviewed our practice of computed tomography (CT)-guided percutaneous transthoracic needle biopsy of pulmonary metastatic lesions with particular emphasis on diagnostic accuracy and nature of complications lesions. MATERIALS & METHODS 25 patients with metastatic lesions of the lung have been evaluated between May 2010 and February...

متن کامل

Predictors of Technical Success and Rate of Complications of Image-Guided Percutaneous Transthoracic Lung Needle Biopsy of Pulmonary Tumors

PURPOSE To investigate predictors of technical success and complications of computed tomography (CT)-guided percutaneous transthoracic needle biopsy of potentially malignant pulmonary tumors. MATERIAL AND METHODS From 2008 to 2009, technical success and rate of complications of CT-guided percutaneous transthoracic lung needle biopsies of patients with suspicious pulmonary tumors were retrospe...

متن کامل

تعیین ارزش تشخیصی بیوپسی سوزنی ترانس توراسیک با راهنمایی سونوگرافی در تشخیص توده‌های محیطی ریه

Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the South African Veterinary Association

دوره 83 1  شماره 

صفحات  -

تاریخ انتشار 2012