Elimination Of Leakage Current In Transformerless CMI Based PV System

نویسنده

  • R. Padmapriya
چکیده

In the renewable energy sources, PV system forms the reliable for power generation. Thus the transformerless CMI is considered to be the best alternative for low cost and high efficiency photovoltaic systems. Eliminating the leakage current is one of the most important issues for transformerless inverters in grid-connected photovoltaic system applications, where the technical challenge is how to keep the system common-mode voltage constant to reduce the leakage current. However due to the result of leakage current resulted from the parasitic capacitance efficiency and reliability is reduced. The leakage current caused due to common mode and differential mode voltage is also reduced in this paper is also analysed.So the problem due to transformerless PV inverter should be tackled carefully. In this paper the basic H –bridge is replaced by QZSI because it offers low impedance to high frequency harmonics. The QZSI circuit differs from that of a conventional ZSI in the LC impedance network interface between the source and inverters. Thus filter based suppression solution is used to reduce the leakage current. Thus analysis and solution for elimination of leakage current is done and verified using simulation tool MATLAB and result is obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Approach for Reactive Power Control of Single Phase Transformerless Inverter to Modify Power Quality in Stand Alone Micro-Grids with Current Leakage Elimination

Nowadays there has been an increasing interest in transformerless inverter for grid-connected photovoltaic (PV) system due to low cost, high efficiency and light weight. One of the reasons describe the grid behavior is capability of reactive power control by inverter. According to the standard VDE-AR-N 4105, grid-tied PV inverter of power rating below 3.68KVA, should attain power factor (PF) fr...

متن کامل

Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...

متن کامل

A Grid Connected Transformerless Inverter and its Model Predictive Control Strategy with Leakage Current Elimination Capability

This paper proposes a new single phase transformerless Photovoltaic (PV) inverter for grid connected systems. It consists of six power switches, two diodes, one capacitor and filter at the output stage. The neutral of the grid is directly connected to the negative terminal of the source. This results in constant common mode voltage and zero leakage current. Model Predictive Controller (MPC) tec...

متن کامل

An Improved Transformerless Grid-Connected PV System With Related Control Strategy to Reduce Leakage Current, Extract Maximum Power Point and Control Power

The main purposes of a transformerless grid-connected photovoltaic (PV) system consist of the reduction of leakage current, extraction of maximum power point (MPP), tracking of MPP (MPPT), controlling the active and reactive powers, and having the unity power factor. To achieve the above-mentioned aims, the following actions have been performed in this paper. First of all, a brief analysis of t...

متن کامل

Space Vector Modulation Technique to Reduce Leakage Current of a Transformerless Three-Phase Four-Leg Photovoltaic System

Photovoltaic systems integrated to the grid have received considerable attention around the world. They can be connected to the electrical grid via galvanic isolation (transformer) or without it (transformerless). Despite making galvanic isolation, low frequency transformer increases size, cost and losses. On the other hand, transformerless PV systems increase the leakage current (common-mode c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015