Exploring the initial steps of the testing process: frequency and nature of pre-preanalytic errors.

نویسندگان

  • Paolo Carraro
  • Tatiana Zago
  • Mario Plebani
چکیده

BACKGROUND Few data are available on the nature of errors in the so-called pre-preanalytic phase, the initial steps of the testing process. We therefore sought to evaluate pre-preanalytic errors using a study design that enabled us to observe the initial procedures performed in the ward, from the physician's test request to the delivery of specimens in the clinical laboratory. METHODS After a 1-week direct observational phase designed to identify the operating procedures followed in 3 clinical wards, we recorded all nonconformities and errors occurring over a 6-month period. Overall, the study considered 8547 test requests, for which 15 917 blood sample tubes were collected and 52 982 tests undertaken. RESULTS No significant differences in error rates were found between the observational phase and the overall study period, but underfilling of coagulation tubes was found to occur more frequently in the direct observational phase (P = 0.043). In the overall study period, the frequency of errors was found to be particularly high regarding order transmission [29 916 parts per million (ppm)] and hemolysed samples (2537 ppm). The frequency of patient misidentification was 352 ppm, and the most frequent nonconformities were test requests recorded in the diary without the patient's name and failure to check the patient's identity at the time of blood draw. CONCLUSION The data collected in our study confirm the relative frequency of pre-preanalytic errors and underline the need to consensually prepare and adopt effective standard operating procedures in the initial steps of laboratory testing and to monitor compliance with these procedures over time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arabic News Articles Classification Using Vectorized-Cosine Based on Seed Documents

Besides for its own merits, text classification (TC) has become a cornerstone in many applications. Work presented here is part of and a pre-requisite for a project we have overtaken to create a corpus for the Arabic text process. It is an attempt to create modules automatically that would help speed up the process of classification for any text categorization task. It also serves as a tool for...

متن کامل

Frequency of Errors in Clinical Laboratory Practice

  Background and Objective: Laboratory errors are one of the major factors that affect the diagnosis, prognosis, treatment and monitoring in patients.The objective of study is to evaluate the frequency and type of errors in different phases of testing at the Pathology Department of the Shalamar Hospital, Lahore and to evaluate the causes of errors. Methods: This observational study was carrie...

متن کامل

Exploring the Role of Occurring Errors Distribution in the Distribution of Corrective Feedback Targets

This study attempted to compare corrected linguistic errors in foreign language classrooms and all errors occurring in these classes to see which types of errors are more attended to by teachers in relation to their occurrence in classes. For this purpose, 69 hours of the classes of 34 teachers teaching in different language schools were recorded and the errors corrected by these teachers were ...

متن کامل

HEART assessment of human error by the hospital operating rooms staff Imam Hussein (AS) and provide solutions Golpayegan city prioritized

Considering the importance of medical care and especially occupations in the operating room for the improvement of illnesses as well as the preservation of life, the consequences of failure and failure to perform the duties of the staff of these centers will be irreparable, so the findings of this study can be a useful guide to reduce Errors in operating room staff. Methods: This study was per...

متن کامل

Frequency of Technical Errors in the Biopsy Samples Submitted to an Oral and Maxillofacial Pathology Laboratory

Background and aim: Following a correct biopsy protocol is crucial for accurate diagnosis of oral and maxillofacial lesions. Pre-analysis technical errors during preparation and submission of biopsies can jeopardize the diagnostic process and the related treatment plan. The aim of the present study was to evaluate pre-analysis technical errors in the biopsy samples submitted to an oral and maxi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 58 3  شماره 

صفحات  -

تاریخ انتشار 2012