Low-dose CT for quantitative analysis in acute respiratory distress syndrome

نویسندگان

  • Vittoria Vecchi
  • Thomas Langer
  • Massimo Bellomi
  • Cristiano Rampinelli
  • Kevin K Chung
  • Leopoldo C Cancio
  • Luciano Gattinoni
  • Andriy I Batchinsky
چکیده

INTRODUCTION The clinical use of serial quantitative computed tomography (CT) to characterize lung disease and guide the optimization of mechanical ventilation in patients with acute respiratory distress syndrome (ARDS) is limited by the risk of cumulative radiation exposure and by the difficulties and risks related to transferring patients to the CT room. We evaluated the effects of tube current-time product (mAs) variations on quantitative results in healthy lungs and in experimental ARDS in order to support the use of low-dose CT for quantitative analysis. METHODS In 14 sheep chest CT was performed at baseline and after the induction of ARDS via intravenous oleic acid injection. For each CT session, two consecutive scans were obtained applying two different mAs: 60 mAs was paired with 140, 15 or 7.5 mAs. All other CT parameters were kept unaltered (tube voltage 120 kVp, collimation 32 × 0.5 mm, pitch 0.85, matrix 512 × 512, pixel size 0.625 × 0.625 mm). Quantitative results obtained at different mAs were compared via Bland-Altman analysis. RESULTS Good agreement was observed between 60 mAs and 140 mAs and between 60 mAs and 15 mAs (all biases less than 1%). A further reduction of mAs to 7.5 mAs caused an increase in the bias of poorly aerated and nonaerated tissue (-2.9% and 2.4%, respectively) and determined a significant widening of the limits of agreement for the same compartments (-10.5% to 4.8% for poorly aerated tissue and -5.9% to 10.8% for nonaerated tissue). Estimated mean effective dose at 140, 60, 15 and 7.5 mAs corresponded to 17.8, 7.4, 2.0 and 0.9 mSv, respectively. Image noise of scans performed at 140, 60, 15 and 7.5 mAs corresponded to 10, 16, 38 and 74 Hounsfield units, respectively. CONCLUSIONS A reduction of effective dose up to 70% has been achieved with minimal effects on lung quantitative results. Low-dose computed tomography provides accurate quantitative results and could be used to characterize lung compartment distribution and possibly monitor time-course of ARDS with a lower risk of exposure to ionizing radiation. A further radiation dose reduction is associated with lower accuracy in quantitative results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute Respiratory Distress Syndrome in a Patient With Suspected Influenza: A Case Report

Acute Respiratory Distress Syndrome (ARDS) is a clinical syndrome consisting of tachypnea, refractory hypoxemia, and diffuse opacities on chest radiographs after infection or trauma which ultimately leads to respiratory failure. The principles of treatment are based on patient care in ICU, mechanical ventilation and medical treatments. By using lower plateau, less tidal volume, higher positive ...

متن کامل

Hypersensitivity Reaction and Acute Respiratory Distress Syndrome in Pyrethroid Poisoning and Role of Steroid Therapy

Background: Pyrethroids are generally of low toxicity to humans, but in suicidal poisonings which are usually associated with ingestion of high doses, they lead to severe systemic effects. Case Report: A 30-year old woman presented to emergency department with a history of intentional ingestion of about 15 mL of prallethrin around 3 days earlier. She complained of shortness of breath along with...

متن کامل

Validity of Spo2/Fio2 Ratio in Detection of Acute Lung Injury and Acute Respiratory Distress Syndrome

Introduction:  One ofdiagnostic criteria for Acute Lung Injury and Acute Respiratory Distress Syndrome is  pao2/fio2 (PF) ratio 300 for ALI or 200 for ARDS. This criteria requires invasive arterial sampling. Measurement of Spo2/Fio2 (SF) ratio by pulseoximetry may be a reliable non invasive alternative to the PF ratio.   Methods and Materials: In a cross sectional study we enrolled 105 sample o...

متن کامل

Rhabdomyolysis and Acute Respiratory Distress Syndrome Secondary to Multiple Wasp Stings

Background: Wasp stings usually cause local reactions such as itching, urticaria, angioedema and anaphylaxis. Life-threatening complications following multiple wasp stings are relatively rare and unexpected. However, rhabdomyolysis and acute respiratory distress syndrome following wasp stings are possible. Case presentation: A middle-aged male worker was stung by a swarm of wasps all over his b...

متن کامل

Lung protection strategy as an effective treatment in acute respiratory distress syndrome

Lung protection strategy as an effective treatment in acute respiratory distress syndrome

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2013