Fast three-dimensional black-blood MR imaging for carotid artery intra-plaque haemorrhage using DANTE-prepared FLASH (3D-DASH)

نویسندگان

  • Linqing Li
  • Luca Biasiolli
  • Joshua T Chai
  • Matthew D Robson
  • Robin P Choudhury
  • Ashok Handa
  • Peter Jezzard
چکیده

Background DANTE (Delays Alternating with Nutation for Tailored Excitation) pulse trains are a rapid series of low flip angle RF pulses interspersed with gradients. We have previously demonstrated that when using DANTE pulse trains as a preparation module prior to imaging readout, the longitudinal magnetization of flowing spins is substantially attenuated, whereas the longitudinal magnetization of static tissue/fluid is mostly preserved [1]. In this study we introduce a new DANTE-prepared 3D FLASH T1 weighted (T1w) sequence (denoted ‘3DDASH’) [2] that is able to generate 0.6 mm isotropic resolution images with an average imaging speed better than 2 sec/slice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An optimized 3D inversion recovery prepared fast spoiled gradient recalled sequence for carotid plaque hemorrhage imaging at 3.0 T.

An optimized 3D inversion recovery prepared fast spoiled gradient recalled sequence (IR FSPGR) on a 3-T scanner for carotid plaque imaging is described. It offers clear blood and fat signal suppression at the carotid artery bifurcation and highlights the regions of carotid plaque affected by hemorrhage at 3 T with high contrast and contrast-to-noise ratio compared with other sequences. It can p...

متن کامل

Preoperative 3D FSE T1-Weighted MR Plaque Imaging for Severely Stenotic Cervical ICA: Accuracy of Predicting Emboli during Carotid Endarterectomy

The aim of the present study was to determine whether preoperative three-dimensional (3D) fast spin-echo (FSE) T1-weighted magnetic resonance (MR) plaque imaging for severely stenotic cervical carotid arteries could accurately predict the development of artery-to-artery emboli during exposure of the carotid arteries in carotid endarterectomy (CEA). Seventy-five patients underwent preoperative M...

متن کامل

Carotid plaque assessment using fast 3D isotropic resolution black-blood MRI.

Black-blood MRI is a promising tool for carotid atherosclerotic plaque burden assessment and compositional analysis. However, current sequences are limited by large slice thickness. Accuracy of measurement can be improved by moving to isotropic imaging but can be challenging for patient compliance due to long scan times. We present a fast isotropic high spatial resolution (0.7×0.7×0.7 mm3) thre...

متن کامل

Observer performance in characterization of carotid plaque texture and surface characteristics with 3D versus 2D ultrasound

OBJECTIVE To determine the reproducibility of three-dimensional (3D) ultrasound (US) over two-dimensional (2D) US in characterizing atherosclerotic carotid plaques using inter- and intra-observer agreement metrics. METHODS A Total of 51 patients with 105 carotid artery plaques were screened using 3D and 2D US probes attached to the same US scanner. Two independent observers characterized the ...

متن کامل

Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls.

This work developed a three-dimensional (3D) diffusion-prepared segmented steady-steady free precession (DP-SSFP) cardiovascular magnetic resonance (CMR) sequence for black-blood (BB) thoracic aortic and carotid wall visualization. In 14 healthy volunteers, BB CMR of the thoracic aorta (n = 7) and carotid arteries (n = 7) was performed over 12 cm and 3 cm of transversal coverage, respectively, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014