Fetal cardiac abnormalities identified prior to 14 weeks' gestation.

نویسندگان

  • I C Huggon
  • T Ghi
  • A C Cook
  • N Zosmer
  • L D Allan
  • K H Nicolaides
چکیده

OBJECTIVE An increasing number of patients are presenting at early gestational age as being at high risk for congenital heart disease, as a result of ultrasound screening by nuchal translucency. The feasibility and accuracy of fetal echocardiography was assessed in a series of pregnancies studied before 14 weeks' gestation. METHODS Echocardiography was attempted in 478 fetuses of crown-rump length 40.0-85.0 mm (median, 60.3 mm) with increased nuchal translucency, suspected abnormalities on routine scan or a family history of heart defect. The findings were related to results of autopsy, karyotyping, later scans and postnatal follow-up. RESULTS Satisfactory images were obtained transabdominally in 402/478 (84.1%) and transvaginally in a further 13 patients. Cardiac defects were confidently identified in 60 fetuses and abnormalities of uncertain significance (isolated ventricular or great artery disproportion, or tricuspid regurgitation) were observed in a further 49. Defects were suspected in an additional 20 fetuses, and 286 were passed as normal. The karyotype was subsequently demonstrated to be abnormal in 70/286 (24.5%) fetuses with normal echocardiograms, and in 94/129 (72.9%) with abnormal or suspicious cardiac findings. Validation of the scan findings was possible in 241 fetuses. Normal heart structure was confirmed in 204 fetuses, and previously unsuspected cardiac abnormalities revealed in nine. Heart defects were verified in 28 fetuses, but five of these had important additional findings. There were false positive findings in three fetuses. CONCLUSIONS Fetal echocardiography is feasible prior to 14 weeks' gestation. Cardiac defects, when present, may be identified or suspected in the majority of cases. In the risk group studied, heart defects were frequently a manifestation of chromosomal abnormality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First-trimester nuchal translucency measurement and echocardiography at 16 to 18 weeks of gestation in prenatal detection for trisomy 18.

BACKGROUND Trisomy 18, the second most common autosomal trisomy, has the highest incidence of congenital heart disease of all chromosomal abnormalities. This study assessed the use of nuchal translucency (NT) measurement and fetal echocardiography at 16 to 18 weeks of gestation in prenatal detection for trisomy 18. METHODS Screening for chromosomal aneuploidy using fetal NT measurement was pe...

متن کامل

Early Evaluation of the Fetal Heart

Evaluation of the fetal heart at 11–13 + 6 weeks of gestation is indicated for women with a family history of congenital heart defects (CHD), a previous child with CDH, or an ultrasound finding associated with cardiac anomalies. The accuracy for early detection of CHD is highly related to the experience of the operator. The 4-chamber view and outflow tracts are the most important planes for ide...

متن کامل

Early Evaluation of the Fetal Heart.

Evaluation of the fetal heart at 11-13 + 6 weeks of gestation is indicated for women with a family history of congenital heart defects (CHD), a previous child with CDH, or an ultrasound finding associated with cardiac anomalies. The accuracy for early detection of CHD is highly related to the experience of the operator. The 4-chamber view and outflow tracts are the most important planes for ide...

متن کامل

بررسی اختلالات مادرزادی بوسیله سونوگرافی معده جنین

Ultrasound study of fetal stomach is multidirectionally rewarding . It can be used to detect congenital aberrations and to estimate gestational age in comparison with biparietal diamater (BPD). This study was performed in 60 pregnant women in 14-40 weeks of gestation. Maximum width and lengths of fetal stomach were measured and compared with BPD in order to determine gestational age . In 4 fetu...

متن کامل

Cardiac defects in chromosomally normal fetuses with abnormal ductus venosus blood flow at 10-14 weeks.

OBJECTIVE To assess a possible relationship between ductus venosus blood flow abnormalities and cardiac defects in chromosomally normal fetuses with increased nuchal translucency thickness at 10-14 weeks of gestation. METHODS Ductus venosus Doppler ultrasound blood flow velocity waveforms were obtained at 10-14 weeks' gestation immediately before fetal karyotyping in 200 consecutive singleton...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2002