The incidence of unacceptable movement with motor evoked potentials during craniotomy for aneurysm clipping.

نویسندگان

  • Laura B Hemmer
  • Carine Zeeni
  • John F Bebawy
  • Bernard R Bendok
  • Mathew A Cotton
  • Neil B Shah
  • Dhanesh K Gupta
  • Antoun Koht
چکیده

OBJECTIVE To review the experience at a single institution with motor evoked potential (MEP) monitoring during intracranial aneurysm surgery to determine the incidence of unacceptable movement. METHODS Neurophysiology event logs and anesthetic records from 220 craniotomies for aneurysm clipping were reviewed for unacceptable patient movement or reason for cessation of MEPs. Muscle relaxants were not given after intubation. Transcranial MEPs were recorded from bilateral abductor hallucis and abductor pollicis muscles. MEP stimulus intensity was increased up to 500 V until evoked potential responses were detectable. RESULTS Out of 220 patients, 7 (3.2%) exhibited unacceptable movement with MEP stimulation-2 had nociception-induced movement and 5 had excessive field movement. In all but one case, MEP monitoring could be resumed, yielding a 99.5% monitoring rate. CONCLUSIONS With the anesthetic and monitoring regimen, the authors were able to record MEPs of the upper and lower extremities in all patients and found only 3.2% demonstrated unacceptable movement. With a suitable anesthetic technique, MEP monitoring in the upper and lower extremities appears to be feasible in most patients and should not be withheld because of concern for movement during neurovascular surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of false-negative/positive results of intraoperative evoked potential monitoring between no and partial neuromuscular blockade in patients receiving propofol/remifentanil-based anesthesia during cerebral aneurysm clipping surgery

Although the elicited responses of motor evoked potential (MEP) monitoring are very sensitive to suppression by anesthetic agents and muscle relaxants, the use of neuromuscular blockade (NMB) during MEP monitoring is still controversial because of serious safety concerns and diagnostic accuracy. Here, we evaluated the incidence of unacceptable movement and compared false-negative MEP results be...

متن کامل

A Case of Thrombosed Giant Aneurysm of the Azygos Anterior Cerebral Artery: Clipping under Monitoring of Motor Evoked Potentials of the Lower Extremities

Giant aneurysms of the distal anterior cerebral artery (ACA), especially the azygos ACA, are rare. We treated a patient with giant aneurysm of the azygos ACA who underwent aspiration of thrombus and clipping under monitoring of motor evoked potentials of the lower extremities (L-MEPs), resulting in remarkable recovery of motor and intellectual function. A 72-year-old male was admitted with left...

متن کامل

Intraoperative Somatosensory and Motor Evoked Potential Recording and Electroencephalographic Monitoring Usefulness During Aneurysm Surgery

In the last 20 years, there have been advances in techniques and instrumentation for intracranial aneurysm exposure and obliteration [94]. However, it seems that 32% of the patients, who underwent surgery, suffer a fatal outcome or some form of sequelae [20]. Primary brain damage due to subarachnoid haemorrhage (SAH) and to a vasospasm, is the major cause of mortality and morbidity; but surgery...

متن کامل

Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal

Introduction: Transcranial magnetic stimulation (TMS) is a useful tool for assessment of corticospinal excitability (CSE) changes in both healthy individuals and patients with brain disorders. The usefulness of TMS-elicited motor evoked potentials (MEPs) for the assessment of CSE in a clinical context depends on their intra-and inter-session reliability. This study aimed to evaluate if removal ...

متن کامل

Real-Time Evaluation of Anterior Choroidal Artery Patency During Aneurysm Clipping.

Inadvertent occlusion of the anterior choroidal artery during aneurysm clipping can cause a disabling stroke in minutes. We evaluate the clinical utility of direct cortical motor evoked potential (MEP) monitoring during aneurysm clipping, as a real-time assessment of arterial patency, prior to performing indocyanine green videoangiography.   Direct cortical MEPs were recorded in seven patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • World neurosurgery

دوره 81 1  شماره 

صفحات  -

تاریخ انتشار 2014