Importance of continuous chest compressions during cardiopulmonary resuscitation: improved outcome during a simulated single lay-rescuer scenario.

نویسندگان

  • Karl B Kern
  • Ronald W Hilwig
  • Robert A Berg
  • Arthur B Sanders
  • Gordon A Ewy
چکیده

BACKGROUND Interruptions to chest compression-generated blood flow during cardiopulmonary resuscitation (CPR) are detrimental. Data show that such interruptions for mouth-to-mouth ventilation require a period of "rebuilding" of coronary perfusion pressure to obtain the level achieved before the interruption. Whether such hemodynamic compromise from pausing to ventilate is enough to affect outcome is unknown. METHODS AND RESULTS Thirty swine (weight 35 +/- 2 kg) underwent 3 minutes of untreated ventricular fibrillation before 12 minutes of basic life support CPR. Animals were randomized to receive either standard airway (A), breathing (B), and compression (C) CPR with expired-gas ventilation in a 15:2 compression-to-ventilation ratio or continuous chest compression CPR. Those randomized to the standard 15:2 group had no chest compressions for a period of 16 seconds each time the 2 ventilations were delivered. Defibrillation was attempted at 15 minutes of cardiac arrest. All resuscitated animals were supported in an intensive care environment for 1 hour, then in a maintenance facility for 24 hours. The primary end point of neurologically normal 24-hour survival was significantly better in the experimental group receiving continuous chest compression CPR (12 of 15 versus 2 of 15; P<0.0001). CONCLUSIONS Mouth-to-mouth ventilation performed by single layperson rescuers produces substantial interruptions in chest compression-supported circulation. Continuous chest compression CPR produces greater neurologically normal 24-hour survival than standard ABC CPR when performed in a clinically realistic fashion. Any technique that minimizes lengthy interruptions of chest compressions during the first 10 to 15 minutes of basic life support should be given serious consideration in future efforts to improve outcome results from cardiac arrest.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه احیای قلبی ریوی پایه در حالت های استاندارد و بالای سر بدون استفاده از آمبوبگ

Background and purpose: One person cardiopulmonary resuscitation (CPR) has a significant role in the survival of cardiac arrest victims. In this study, two techniques of single-rescuer CPR and over-the-head CPR with mouth-to-mouth ventilation were compared. Materials and methods: This crossover study was carried out among 100 medical students who were previously trained in CPR. They performed ...

متن کامل

Quality of continuous chest compressions performed for one or two minutes

OBJECTIVES This study was designed to assess cardiopulmonary resuscitation quality and rescuer fatigue when rescuers perform one or two minutes of continuous chest compressions. METHODS This prospective crossover study included 148 lay rescuers who were continuously trained in a cardiopulmonary resuscitation course. The subjects underwent a 120-min training program comprising continuous chest...

متن کامل

Optimizing chest compression to rescue ventilation ratios during one-rescuer CPR by professionals and lay persons: children are not just little adults.

OBJECTIVE To estimate the optimum ratio of chest compressions to ventilations for one-rescuer CPR that maximizes systemic oxygen delivery in children. METHOD Equations describing oxygen delivery and blood flow during CPR as functions of the number of compressions and the number of ventilations delivered over time were adapted from the former work of Babbs and Kern. These equations were solved...

متن کامل

Comparing three CPR feedback devices and standard BLS in a single rescuer scenario: a randomised simulation study.

BACKGROUND Efficiently performed basic life support (BLS) after cardiac arrest is proven to be effective. However, cardiopulmonary resuscitation (CPR) is strenuous and rescuers' performance declines rapidly over time. Audio-visual feedback devices reporting CPR quality may prevent this decline. We aimed to investigate the effect of various CPR feedback devices on CPR quality. METHODS In this ...

متن کامل

Comparison of the Effects of Three Different Counting Methods on Cardiopulmonary Resuscitation Quality and Rescuer Fatigue

Background: Chest compression with adequate depth and number is one of the main indicators of high-quality cardiopulmonary resuscitation (CPR). Nevertheless, no proper counting technique is suggested to provide sufficient number of massages. Aim: To compare the effects of three techniques of chest compression counting on the quality of CPR and rescuer fatigue. Method: Inthis clinical trial, 30 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 105 5  شماره 

صفحات  -

تاریخ انتشار 2002