Quantifying coronary sinus flow and global LV perfusion at 3T
نویسندگان
چکیده
BACKGROUND Despite the large availability of 3T MR scanners and the potential of high field imaging, this technical platform has yet to prove its usefulness in the cardiac MR setting, where 1.5T remains the established standard. Global perfusion of the left ventricle, as well as the coronary flow reserve (CFR), can provide relevant diagnostic information, and MR measurements of these parameters may benefit from increased field strength. Quantitative flow measurements in the coronary sinus (CS) provide one method to investigate these parameters. However, the ability of newly developed faster MR sequences to measure coronary flow during a breath-hold at 3T has not been evaluated. METHODS The aim of this work was to measure CS flow using segmented phase contrast MR (PC MR) on a clinical 3T MR scanner. Parallel imaging was employed to reduce the total acquisition time. Global LV perfusion was calculated by dividing CS flow with left ventricular (LV) mass. The repeatability of the method was investigated by measuring the flow three times in each of the twelve volunteers. Phantom experiments were performed to investigate potential error sources. RESULTS The average CS flow was determined to 88 +/- 33 ml/min and the deduced LV perfusion was 0.60 +/- 0.22 ml/min.g, in agreement with published values. The repeatability (1-error) of the three repeated measurements in each subject was on average 84%. CONCLUSION This work demonstrates that the combination of high field strength (3T), parallel imaging and segmented gradient echo sequences allow for quantification of the CS flow and global perfusion within a breath-hold.
منابع مشابه
Comparison of the Efficacy of Conventional Echocardiographic Parameters in the Diagnosis of Significant Coronary Artery Stenosis
BACKGROUND For diagnosis of significant coronary artery stenosis, the most accurate parameter among the conventional echocardiographic parameters remains unknown. OBJECTIVES To assess the diagnostic efficacy of conventional echocardiographic parameters in the diagnosis of significant coronary artery stenosis and their correlation with the percentage of stenosis considering conventional corona...
متن کاملComparison between Diastolic Subendocardial Tissue Pressures Measured Directly or Calculated from Pressure-Flow Relations
Changes in intramyocardial tissue pressure modulate the relationship between coronary pressure and flow during the cardiac cycle. The present study compared the relation between measured and calculated diastolic subendocardial tissue pressure and coronary pressure at zero flow in anesthetized dogs after modulation of either coronary sinus (i.e. Fogarty catheter) or left ventricular intracavity ...
متن کاملPatients with Cardiac syndrome X have decreased global myocardial perfusion compared to gender matched controls; insights from CMR coronary sinus flow measurements
Methods Thirteen CSX patients (64 ± 12SD years, 9 females), here defined as a history of chest pain and pathological ECG reaction during stress (> 1 mm ST-depression at stress or after 4 minutes of recovery) but normal myocardial perfusion assessed by myocardial perfusion scintigraphy (SPECT), were included. In addition, 15 positive controls (66 ± 9SD years, 6 females) with stress-induced perfu...
متن کاملComparative effects of hypoxia and ischemia in the isolated, blood-perfused dog heart: evaluation of left ventricular diastolic chamber distensibility and wall thickness.
To compare the effects of hypoxia and ischemia on left ventricular (LV) diastolic function, we studied 17 isolated, isovolumic dog hearts by measuring LV diastolic chamber distensibility (LV end diastolic pressure at constant volume), wall thickness, and myocardial pH in response to hypoxia at constant coronary flow or pressure versus global ischemia (zero coronary blood flow). Hypoxic perfusat...
متن کاملCombined Assessment of Stress Myocardial Perfusion Cardiovascular Magnetic Resonance and Flow Measurement in the Coronary Sinus Improves Prediction of Functionally Significant Coronary Stenosis Determined by Fractional Flow Reserve in Multivessel Disease
BACKGROUND Recent studies using stress-rest perfusion cardiovascular magnetic resonance (CMR) demonstrated a close correlation between myocardial ischemia and reduced fractional flow reserve (FFR). However, its diagnostic concordance may be reduced in patients with multivessel disease. We sought to evaluate the concordance of adenosine stress-rest perfusion CMR for predicting reduced FFR, and t...