Cervical vertebral motions and biomechanical responses to direct loading of human head.

نویسندگان

  • Koshiro Ono
  • Koji Kaneoka
  • Shinichiro Hattori
  • Sadayuki Ujihashi
  • Eric G Takhounts
  • Mark P Haffner
  • Rolf H Eppinger
چکیده

There is little known data characterizing the biomechanical responses of the human head and neck under direct head loading conditions. However, the evaluation of the appropriateness of current crash test dummy head-neck systems is easily accomplished. Such an effort, using experimental means, generates and provides characterizations of human head-neck response to several direct head loading conditions. Low-level impact loads were applied to the head and face of volunteers and dummies. The resultant forces and moments at the occipital condyle were calculated. For the volunteers, activation of the neck musculature was determined using electromyography (EMG). In addition, cervical vertebral motions of the volunteers have been taken by means of X-ray cineradiography. The Ethics Committee of Tsukuba University approved the protocol of the experiments in advance. External force of about 210 N was applied to the head and face of five volunteers with an average age of 25 for the duration of 100 msec or so, via a strap at one of four locations in various directions: (1) an upward load applied to the chin, (2) a rearward load applied to the chin without facial mask, (3) a rearward load applied to the chin with the facial mask, and (4) a rearward load applied to the forehead. The same impact force as those for the human volunteers was also applied to HY-III, THOR, and BioRID. We found that cervical vertebral motions differ markedly according to the difference in impact loading condition. Some particular characteristics are also found, such as the flexion or extension of the upper cervical vertebrae (C0, C1, and C2) or middle cervical vertebrae (C3-C4), showing that the modes of cervical vertebral motions are markedly different among the different loading conditions. We also found that the biofidelity of dummies to neck response characteristics of the volunteers at the low-level impact loads is in the order of BioRID, THOR, and HY-III. It is relevant in this regard that the BioRID dummy was designed for a low-severity impact environment, whereas THOR and HY-III were optimized for higher-severity impacts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Whiplash syndrome: kinematic factors influencing pain patterns.

STUDY DESIGN The overall, local, and segmental kinematic responses of intact human cadaver head-neck complexes undergoing an inertia-type rear-end impact were quantified. High-speed, high-resolution digital video data of individual facet joint motions during the event were statistically evaluated. OBJECTIVES To deduce the potential for various vertebral column components to be exposed to adve...

متن کامل

Finite element analysis of moment-rotation relationships for human cervical spine.

A comprehensive, geometrically accurate, nonlinear C0-C7 FE model of head and cervical spine based on the actual geometry of a human cadaver specimen was developed. The motions of each cervical vertebral level under pure moment loading of 1.0 Nm applied incrementally on the skull to simulate the movements of the head and cervical spine under flexion, tension, axial rotation and lateral bending ...

متن کامل

Biomechanical analysis of blast-induced traumatic brain injury

  Purpose: Blast-induced traumatic brain injury (bTBI) is one of the causes of death or permanent   invalidity which can occur unexpectedly in both military and civilian populations. This study   set out to conduct a combined Eulerian-Lagrangian computational analysis of the interaction   between a single planar blast wave and a human head in order to assess the extent of intracranial   shock w...

متن کامل

Development and validation of a CO-C7 FE complex for biomechanical study.

In this study, the digitized geometrical data of the embalmed skull and vertebrae (C0-C7) of a 68-year old male cadaver were processed to develop a comprehensive, geometrically accurate, nonlinear C0-C7 FE model. The biomechanical response of human neck under physiological static loadings, near vertex drop impact and rear-end impact (whiplash) conditions were investigated and compared with publ...

متن کامل

Biomechanical analyses of whiplash injuries using an experimental model.

Neck pain and headaches are the two most common symptoms of whiplash. The working hypothesis is that pain originates from excessive motions in the upper and lower cervical segments. The research design used an intact human cadaver head-neck complex as an experimental model. The intact head-neck preparation was fixed at the thoracic end with the head unconstrained. Retroreflective targets were p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Traffic injury prevention

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2003