Effects of temperature on Vitalograph spirometer readings.
نویسندگان
چکیده
Spirometric variables were obtained from nine symptomless subjects, who performed forced expiratory manoeuvres with three Vitalograph spirometers at three different ambient temperatures (36.5 degrees C, 24.1 degrees C, and - 7.3 degrees C) over three days according to a Latin square design. Analysis of variance showed no significant difference between values at different ambient temperatures when measured at ATPS. Correction of the results to BTPS resulted in a significant difference in values at the three ambient temperatures for all measurements other than the Vmax25. The mean error introduced by conversion to BTPS varied from 7% (SD 5%) for the FVC at 24.1 degrees C to 30% (21%) for Vmax50 at - 7.3 degrees C. Possible explanations for these observations include the increasing compliance of the spirometer bellows with increasing temperature, relatively slow cooling of gases within the spirometer, and a combination of these effects. We conclude that there is no evidence that conversion to BTPS improves the accuracy of measurements made on a Vitalograph spirometer. Further studies on other spirometers are needed to see whether conversion to BTPS is always appropriate.
منابع مشابه
Temperature corrections in routine spirometry.
Forced expiratory volume (FEV1) and forced vital capacity (FVC) were measured in nine normal subjects with three Vitalograph and three rolling seal spirometers at three different ambient temperatures (4 degrees C, 22 degrees C, 32 degrees C). When the results obtained with the rolling seal spirometer were converted to BTPS the agreement between measurements in the three environments improved, b...
متن کاملEvaluation of a new electronic spirometer: the vitalograph "Escort" spirometer.
BACKGROUND The "Escort" spirometer is a lightweight, hand held spirometer employing a Fleisch pneumotachograph. Measurements of forced expiratory volume in one second (FEV1), forced vital capacity (FVC), and peak expiratory flow (PEF) are obtained from a single FVC manoeuvre. Results are displayed on a small liquid crystal display, but there is no graphical display. The performance of the Escor...
متن کاملEvaluation of the turbine pocket spirometer.
A compact electronic spirometer, the turbine pocket spirometer, which measures the FEV1, forced vital capacity (FVC), and peak expiratory flow (PEF) in a single expiration, was compared with the Vitalograph and the Wright peak flow meter in 99 subjects (FEV1 range 0.40-5.50 litres; FVC 0.58-6.48 l; PEF 40-650 l min-1). The mean differences between the machines were small--0.05 l for FEV1, 0.05 ...
متن کاملFUMEPOC: Early detection of chronic obstructive pulmonary disease in smokers
BACKGROUND Currently is not feasible using conventional spirometry as a screening method in Primary Care especially among smoking population to detect chronic obstructive pulmonary disease in early stages. Therefore, the FUMEPOC study protocol intends to analyze the validity and reliability of Vitalograph COPD-6 spirometer as simpler tool to aid screening and diagnosis of this disease in early ...