On-line Partial Discharge Assessment and Monitoring of MV to EHV Cables

نویسندگان

  • Neil Davies
  • Victor Chan
چکیده

To effectively manage their electricity networks, owners and operators around the world have a very real need to understand the condition of their often ageing Transmission and Distribution assets. Of all the major asset classes, underground cables often have the least available condition data but at the same time have a significant impact on network performance. One of the predominant causes of cable failure is partial discharge (PD) and collection of PD data can help fill this information gap. This paper discusses the practicalities and application of on-line partial discharge testing and monitoring of cables from MV to EHV.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-Line and Off-line PD monitoring: The Experiences in testing MV and HV apparatus from an Industrial Point of View

In recent years, an increasing demand for partial discharge (PD) testing on medium and high voltages apparatus has been observed. This includes cables, switchgear, transformers and rotating machines, both with on-line (inservice) and off-line (out-of-service) testing/monitoring practices to increase reliability and reduce financial losses due to plant downtime, unplanned outages and expensive m...

متن کامل

Advanced technique for partial discharge detection and analysis in power cables

Polymeric cables are the most common choice for transmission and distribution in populated areas, as well as for the connection of components (transformers, GIS, etc.) in new power stations, replacing paper-oil cables. Indeed, they do possess superior characteristics with respect to oil-filled cables. As an example, they do require lower maintenance, they are lighter (easier to deploy) and, in ...

متن کامل

On-line Partial Discharge Monitoring System and Data Processing Using WTST-NST Filter for High Voltage Power Cable

Defects inside insulation of HV XLPE cable accessories can lead to partial discharge (PD) activity. When PD activity happens, leakage current may flow through the grounded line. To acquire the PD current signal, one practicable and effective method is placing a high frequency current transformer (HFCT) winding the grounded line. In order to measure the insulation degradation, a partial discharg...

متن کامل

Power Cable Protection in Transmission System

Power cable is widely used in Extra High Voltage (EHV), High Voltage (HV) transmission, Medium Voltage (MV) sub-transmission, and MV / Low Voltage (LV) distribution applications. Basically, the protection principles used for cable are similar with the ones for overhead transmission line. However, the inherent characteristics of cables make its fault behavior more complicate than that of transmi...

متن کامل

Condition Monitoring of Power Cables

A National Grid funded research project at Southampton has investigated possible methodologies for data acquisition, transmission and processing that will facilitate on-line continuous monitoring of partial discharges in high voltage polymeric cable systems. A method that only uses passive components at the measuring points has been developed and is outlined in this paper. More recent work, fun...