An observation model for motion correction in nuclear medicine

نویسندگان

  • Majdi R. Alnowami
  • Emma Lewis
  • Matthew Guy
  • Kevin Wells
چکیده

This paper describes a method of using a tracking system to track the upper part of the anterior surface during scanning for developing patient-specific models of respiration. In the experimental analysis, the natural variation in the anterior surface during breathing will be modeled to reveal the dominant pattern in the breathing cycle. The main target is to produce a patient-specific set of parameters that describes the configuration of the anterior surface for all respiration phases. These data then will be linked to internal organ motion to identify the effect of the morphology of each on motion using particle filter to account for previously unseen patterns of motion. In this initial study, a set of volunteers were imaged using the Codamotion infrared marker-based system. In the marker-based system, the temporal variation of the respiratory motion was studied. This showed that for the 12 volunteer cohort, the mean displacement of the thorax surface TS ( abdomen surface AS) region is 10.7± 5.6 mm (16.0± 9.5mm). Finally, PCA was shown to capture the redundancy in the data set with the first principal component (PC) accounting for more than 96% of the overall variance in both AS and TS datasets . A fitting to the dominant modes of variation using a simple piecewise sinusoid has suggested a maximum error of about 1.1mm across the complete cohort dataset.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

متن کامل

A new approach to scatter correction in SPECT images based on Klein_Nishina equation

Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique ...

متن کامل

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Recursive Bayesian estimation of respiratory motion using a modified autoregressive transition model

Compensation for respiratory motion has been identified as a crucial factor in achieving high resolution Nuclear Medicine (NM) imaging. Many motion correction approaches have been studied and they are seen to have advantages over simpler approaches such as respiratory gating. However, all motion correction approaches rely on an assumption or estimation of respiratory motion. This paper builds u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010