Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia
نویسندگان
چکیده
OBJECTIVE To evaluate a sensor-augmented insulin pump with a low glucose suspend (LGS) feature that automatically suspends basal insulin delivery for up to 2 h in response to sensor-detected hypoglycemia. RESEARCH DESIGN AND METHODS The LGS feature of the Paradigm Veo insulin pump (Medtronic, Inc., Northridge, CA) was tested for 3 weeks in 31 adults with type 1 diabetes. RESULTS There were 166 episodes of LGS: 66% of daytime LGS episodes were terminated within 10 min, and 20 episodes lasted the maximum 2 h. LGS use was associated with reduced nocturnal duration ≤2.2 mmol/L in those in the highest quartile of nocturnal hypoglycemia at baseline (median 46.2 vs. 1.8 min/day, P = 0.02 [LGS-OFF vs. LGS-ON]). Median sensor glucose was 3.9 mmol/L after 2-h LGS and 8.2 mmol/L at 2 h after basal restart. CONCLUSIONS Use of an insulin pump with LGS was associated with reduced nocturnal hypoglycemia in those at greatest risk and was well accepted by patients.
منابع مشابه
Cost-Effectiveness Analysis of Sensor-Augmented Insulin Pump Therapy with Automated Insulin Suspension Versus Standard Insulin Pump Therapy in Patients with Type 1 Diabetes in Sweden
INTRODUCTION In Sweden an estimated 10,000 people with type 1 diabetes use continuous subcutaneous insulin infusion (CSII). Sensor-augmented pump therapy (SAP) is associated with higher acquisition costs but provides additional clinical benefits (e.g. reduced rate of hypoglycemic events) over and above that of CSII alone. The aim of the analysis was to assess the cost-effectiveness of SAP with ...
متن کاملAnalysis of Glucose Responses to Automated Insulin Suspension With Sensor-Augmented Pump Therapy
OBJECTIVE The advent of sensor-augmented pump therapy with a low-glucose suspend (LGS) function (Medtronic Paradigm Veo System), allowing insulin to be automatically suspended for up to 2 h when sensor glucose falls below a preset threshold, has the potential to reduce the duration of hypoglycemia. In this article, we analyzed blood glucose profiles following a full 2-h insulin suspension activ...
متن کامل“Let the Algorithm Do the Work”: Reduction of Hypoglycemia Using Sensor-Augmented Pump Therapy with Predictive Insulin Suspension (SmartGuard) in Pediatric Type 1 Diabetes Patients
BACKGROUND A sensor-augmented insulin pump (SAP) using the MiniMed® 640G system with SmartGuard™ technology allows an automatic stop of insulin delivery based on prediction of low glucose levels. Since pediatric patients are particularly prone to hypoglycemia, this device may offer additional protection beyond conventional sensor-augmented therapy. METHODS This prospective, pediatric multicen...
متن کاملASPIRE In-Home: rationale, design, and methods of a study to evaluate the safety and efficacy of automatic insulin suspension for nocturnal hypoglycemia.
Nocturnal hypoglycemia is a barrier to therapy intensification efforts in diabetes. The Paradigm® Veo™ system may mitigate nocturnal hypoglycemia by automatically suspending insulin when a prespecified sensor glucose threshold is reached. ASPIRE (Automation to Simulate Pancreatic Insulin REsponse) In-Home (NCT01497938) was a multicenter, randomized, parallel, adaptive study of subjects with typ...
متن کاملSuspension of basal insulin to avoid hypoglycemia in type 1 diabetes treated with insulin pump
UNLABELLED Treatment with continuous s.c. insulin infusion (CSII) provides better glycemic control and lower risk of hypoglycemia than conventional therapy with multiple daily insulin injections. These benefits have been related to a more reliable absorption and an improved pharmacokinetic profile of insulin delivered through CSII therapy. However, even for patients treated with CSII, exaggerat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 34 شماره
صفحات -
تاریخ انتشار 2011