Measurement of Paradoxical and Coupled Motions Following Lumbar Total Disc Replacement

نویسندگان

  • Soo-An Park
  • Nathaniel Ordway
  • Amir Fayyazi
  • Bruce Fredrickson
  • Hansen A. Yuan
چکیده

BACKGROUND Maintenance of segmental motion following lumbar total disc replacement (LTDR) is one of the theoretical advantages of spinal arthroplasty. This in vivo study examined paradoxical and coupled motions during sagittal plane movements following disc arthroplasty and compared these motions with those measured following lumbar discectomy. METHODS Ten patients following LTDR using ProDisc-L (Synthes, Inc., West Chester, Pennsylvania) and 8 patients following lumbar discectomy (LD) were enrolled. At 1-month, 1-year and 2-year postoperative time-points, patients performed flexion/extension starting from a neutral position, and the intervertebral rotations were determined with radiostereometric analysis. The amount of intended and coupled motion was compared in each group and at each postoperative time. The frequency of paradoxical motion was compared between the 2 groups, and the effects of intended motion, operative-level, number of levels, and postoperative time-point were examined. RESULTS The intended and coupled motions following LTDR and LD did not change over time and did not differ from each other for the flexion and total sagittal movements. The sagittal range of motion (ROM) of LTDR was significantly smaller than that of LD in extension (-0.6° ± 1.1° vs -2.2° ± 1.6°). LTDR exhibited a significantly higher rate of paradoxical motion when compared to LD (26.4% vs 6.7%). In LTDR, the rate of paradoxical motion at 1 month (40%) was significantly higher than at 1-year (21.1%) or at 2-year (25.0%). The presence of paradoxical motion was significantly less frequent at L4-5 (19.2%) when compared to L5-S1 (31.3%) or L2-3 (36.4%). CONCLUSION The overall sagittal ROM of LTDR was 3.5° ± 2.4° and not significantly different than LD. The current study did not demonstrate a difference in coupled motions between LTDR and LD. The rate of paradoxical motion was significantly higher in LTDR than in LD. In LTDR, there was a significantly lower rate of paradoxical motion seen at L4-5 and significantly higher rate seen in the earlier postoperative period. LEVEL OF EVIDENCE Prospective cohort study with good follow-up (level 1b).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinematics of total facet replacement (TFAS-TL) with total disc replacement

BACKGROUND Total disc replacement (TDR) and total facet replacement (TFR) have been the focus of recent kinematics evaluations. Yet their concurrent function as a total joint replacement of the lumbar spine's 3-joint complex has not been comprehensively reported. This study evaluated the effect of a TFR specifically designed to replace the natural facets and supplement the function with the nat...

متن کامل

Biomechanical comparison between lumbar disc arthroplasty and fusion.

The artificial disc is a mobile implant for degenerative disc replacement that attempts to lessen the degeneration of the adjacent elements. However, inconsistent biomechanical results for the neighboring elements have been reported in a number of studies. The present study used finite element (FE) analysis to explore the biomechanical differences at the surgical and both adjacent levels follow...

متن کامل

The activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain

Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR) or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration - the Charité Artificial Disc in 2004 ...

متن کامل

ProDisc artificial total lumbar disc replacement: introduction and early results from the United States clinical trial.

STUDY DESIGN Multicenter prospective randomized study of artificial disc replacement (ProDisc) versus circumferential fusion (standard of care) for one- and two-level degenerative disc disease. This is an interim analysis on patients seen at the Spine Institute Saint John's Health Center, Santa Monica, California. OBJECTIVES To evaluate early pain and functional outcomes of patients treated w...

متن کامل

Recent Advances in Finite Element Applications in Artificial Lumbar Disc Replacement

As a new choice for the treatment of degenerative lumbar disease, artificial lumbar disc replacement has been widely used in clinical surgery. The finite element is a very effective method to predict and simulate the surgery effect. The purpose of this paper is to review the applications of finite element in artificial lumbar disc replacement, such as design of artificial lumbar disc prosthesis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2008