Effect of Imaging Time in the Magnetic Resonance Detection of Intracerebral Metastases Using Single Dose Gadobutrol

نویسندگان

  • Ji-Young Jeon
  • Jin Woo Choi
  • Hong Gee Roh
  • Won-Jin Moon
چکیده

OBJECTIVE To compare the effect of imaging time delay on the MR detection of intracerebral metastases using single dose gadobutrol. MATERIALS AND METHODS Twenty-one patients with intracerebral metastases underwent contrast-enhanced MR with three-dimensional T1-weighted sequence at 1 minute, 5 minutes and 10 minutes after a single dose injection of gadobutrol. One hundred index metastatic lesions (1 to 30 mm; median, 7 mm) were chosen for the analysis. For the qualitative analysis, lesion conspicuity were assessed on a 1 (worst) to 5 (best) scale of the index lesions by an expert reader. For the quantitative analysis, signal intensity (SI) of enhancing lesions and normal parenchyma was measured to determine the contrast rate (CR, %) ([postcontrast SI lesion - postcontrast SI white matter] × 100 / postcontrast SI white matter) and the enhancement rate (ER, %) ([postcontrast SI lesion - baseline SI gray matter] × 100 / baseline SI gray matter). Statistical comparisons were made between three different time delays. RESULTS Lesion conspicuity did not differ significantly among the three time delays (p = 0.097). Although the SI, CR and ER of lesions did not reveal any significant difference between 1 minute and 5 minutes delayed images, both the 1 minute and 5 minutes delayed images showed significantly higher CRs of lesions compared with the 10 minutes delayed images (p = 0.004 and p = 0.001, respectively). CONCLUSION With single dose gadobutrol, imaging time delay did not have an effect on lesion conspicuity. Both 1-minute and 5-minute-delayed imaging after gadobutrol injection appears to be effective for the detection of intracerebral metastases.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

متن کامل

ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST

Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...

متن کامل

In vitro Study of SPIONs-C595 as Molecular Imaging Probe for Specific Breast Cancer (MCF-7) Cells Detection

Background: Magnetic resonance imaging (MRI) plays an essential role in molecular imaging by delivering the contrast agent into targeted cancer cells. The aim of this study was to evaluate the C595 monoclonal antibody-conjugated superparamagnetic iron oxide nanoparticles (SPIONs-C595) for the detection of breast cancer cell (MCF-7). Methods: The conjugation of monoclonal antibody and nanopartic...

متن کامل

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

متن کامل

Safety and Efficacy of Gadobutrol-Enhanced MRI in Patients Aged Under 2 Years—A Single-Center, Observational Study

Gadobutrol is a 1-molar gadolinium-based contrast agent with well-characterized safety and efficacy for magnetic resonance imaging (MRI) in adults and children ≥ 2 years old. This observational study assessed gadobutrol-enhanced MRI in children < 2 years of age. Sixty infants (mean age 11.1 months) underwent MRI using gadobutrol at standard dose of 0.1 mL/kg (0.1 mmol/kg) body weight. MRI exami...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014