The Effects of Bone Screw Configurations on the Interfragmentary Movement in a Long Bone Fixed by a Limited Contact Locking Compression Plate
نویسندگان
چکیده
The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the functionality of the bone plate. Several studies have assessed the influence of the screw configurations on the bone-plate stiffness, but the effects of screw positions on the interfragmentary strain, εIF of LCP construct have not been investigated yet. In this study, finite element method was used to investigate the influence of screws number and position on the interfragmentary strain of LCP-femur system for a mid-shaft fracture. Results of this study showed that by insertion of screws closer to the fracture site, εIF decreases by 2nd degree polynomial function versus screw position, but by adding the screws from the ends of the plate, or by moving and placing the screws towards the fracture site, the reduction of εIF will be linear. Results of this study were compared and are in agreement with some studies in the literature, even though their scope was mostly stability of the bone-implant system, whereas our scope was focused on the interfragmentary strain.
منابع مشابه
A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملDynamics of screw and plate interaction.
Several papers in this issue of the Journal address topics in the theme of plate and screw fixation (1–4). A critical element of this form of internal fixation is that the maintenance of stability provided by the plate relies heavily on the integrity of the screw fixation. Bone screws can perform their work in several ways. In conventional plate fixation, the head of a tightened screw compresse...
متن کاملA biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation.
BACKGROUND Conventional internal fixation entails the use of an interfragmentary lag screw along with a plate. Not all acetabular fractures are amenable to the placement of an interfragmentary lag screw, and the fracture may be displaced during tightening of the interfragmentary lag screw. Locking plates are a possible solution. We sought to determine whether a locking plate construct can provi...
متن کاملA biomechanical study comparing the compressive forces generated by a conventional 4.5 AO/ASIF cortical lag screw with a differentially pitched cortical compression screw.
The aim of this study was to compare the interfragmentary compression generated across a simulated femoral fracture model by a conventional 4.5 mm AO/ASIF cortical lag screw with a differentially pitched cortical compression screw. A 45-degree osteotomy was made in a whole bone composite femoral shaft, this was internally fixed with either a conventional 4.5 mm AO/ASIF cortical lag screw or the...
متن کاملBiomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques
Reliable osteosynthesis of intraarticular fractures depends on lasting interfragmentary compression. Its amount differs in the applied fixation method. The interfragmentary compression of cancellous and cortical lag screws and angle stable locking plates was quantified in an osteoporotic and non-osteoporotic synthetic human bone model.A split fracture of the lateral tibia plateau (AO/OTA type 4...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015