Noninvasive mapping of left ventricular electromechanical asynchrony by three-dimensional echocardiography and semi-automatic contour detection.

نویسندگان

  • Johannes A van der Heide
  • Herman F Mannaerts
  • Hugo J Spruijt
  • Linda M van Campen
  • Carel de Cock
  • Cees A Visser
  • Otto Kamp
چکیده

A system for analyzing left ventricular (LV) electromechanical asynchrony based on transesophageal 3-dimensional echocardiography (3-DE) and semi-automatic endocardial contour detection is described. Eighteen consecutive patients underwent 3-DE. Using TomTec 4DLV software, a 3-dimensional endocardial surface was reconstructed throughout the cardiac cycle. Matlab software generated color-coded polar maps, displaying regional LV displacement and its timing. At the segmental level, Bland-Altmann assessment showed intraobserver variability of LV displacement of 0.1 +/- 3.0 mm and timing of -5.6 +/- 160 ms (bias +/- 2 SD) for all segments and -1.6 +/- 94 ms for the nonapical segments. The combination of 3-DE and semi-automatic contour detection is feasible and provides unique information for assessing regional LV endocardial displacement and electromechanical asynchrony.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran

The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...

متن کامل

Integration of mechanical, structural and electrical imaging to understand response to cardiac resynchronization therapy.

INTRODUCTION AND OBJECTIVES There is extensive controversy exists on whether cardiac resynchronization therapy corrects electrical or mechanical asynchrony. The aim of this study was to determine if there is a correlation between electrical and mechanical sequences and if myocardial scar has any relevant impact. METHODS Six patients with normal left ventricular function and 12 patients with l...

متن کامل

بررسی عوارض قلبی در بیماران مبتلا به تالاسمی ماژور در کاشان در سالهای 1378 لغایت 1379

ABSTRACT Due to the frequency of major thalassemia in our country and cardiac complications secondry to iron overload as one of the most important causes of death in these patients and the absence of any similar study in this region (Kashan city), we studied the cardiac complications in patients with major thalassemia in Kashan in 1999 and 2000. A prospective descriptive study was perf...

متن کامل

Assessment of Left Ventricular Function by Analysis of Volume-Time Curves of 16 Segments with Real-Time Three Dimensional Echocardiography: Left Ventricular Asynchrony as a Clinical Parameter for Patients with Heart Failure

Background and Objectives:Recent technical developments with high-resolution real-time 3-dimensional echocardiography (RT3DE) have facilitated the acquisition of high quality images and the analysis of segmental volumetime curves (VTCs). The purposes of this study were to assess left ventricular (LV) asynchrony with using the VTCs of 16 segments by RT3DE and to compare this with tissue Doppler ...

متن کامل

Assessment of left ventricular mass and volumes by three-dimensional echocardiography in patients with or without wall motion abnormalities: comparison against cine magnetic resonance imaging

AIM To evaluate if three-dimensional echocardiography (3-DE) is as accurate and reproducible as cine magnetic resonance imaging (cMR) in estimating left ventricular (LV) parameters in patients with and without wall motion abnormalities (WMA). METHODS 83 patients (33 with WMA) underwent 3-DE and cMR. 3-DE datasets were analysed using a semi-automatic contour detection algorithm. The accuracy o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of cardiology

دوره 94 11  شماره 

صفحات  -

تاریخ انتشار 2004