Amidolytic assay of human factor XI in plasma: comparison with a coagulant assay and a new rapid radioimmunoassay.

نویسندگان

  • C F Scott
  • D Sinha
  • F S Seaman
  • P N Walsh
  • R W Colman
چکیده

The traditional coagulant assay for plasma factor XI suffers from a relatively high coefficient of variation, the need for rare congenitally deficient plasma, and a poor correlation between precision and sensitivity. We have developed a simple functional amidolytic assay for factor XI in plasma using the chromogenic substrate PyrGlu-Pro-Arg-p-nitroanilide (S-2366). After inactivation of alpha 1-antitrypsin, CI inhibitor, and other plasma protease inhibitors with CHCI3, plasma was incubated with kaolin, in the absence of added calcium, which limited the enzymes formed to those dependent on contact activation. Soybean trypsin inhibitor was used to minimize the action of kallikrein on the substrate. Once the reaction was complete, corn trypsin inhibitor was used to inactive factor XIIa, the enzyme generated by exposure of plasma to negatively charged surfaces, which had activated the factor XI. The assay is highly specific for factor XI, since plasma totally deficient in that zymogen yielded only 1%-3% of the enzymatic activity in normal plasma under identical conditions. The requirements for complete conversion of factor XI to XIa in plasma within 60 min were, respectively, factor XII, 0.6 U/ml, and high molecular weight kininogen, 0.2 U/ml. Prekallikrein was not an absolute requirement for complete activation but did accelerate the reaction. The intraassay coefficient of variation was 3.4%, and the mean of 35 normal plasmas was 1.00 U +/- 0.24 SD. In addition, a new rapid radioimmunoassay was devised using staphylococcal protein A as the precipitating agent for a complex of factor XI antigen with monospecific rabbit antibody. The mean was 1.01 U +/- 0.30 SD. The correlation coefficients for amidolytic versus coagulant and amidolytic versus radioimmunoassay were r = 0.95 for the former and 0.96 for the latter. Thus, a simple, accurate amidolytic assay and a radioimmunoassay have been devised for measuring factor XI in plasma that correlate well with the coagulant activity of factor XI, as determined in our laboratory.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assay of prekallikrein in human plasma: comparison of amidolytic, esterolytic, coagulation, and immunochemical assays.

Using the substrate H-D-Pro-Phe-Arg-p-nitroanilide-HCl, an amidolytic assay was designed to measure prekallikrein in plasma. At a substrate concentration of 1 mM (Km = 0.2 mM), the amidolysis of purified kallikrein at 1 coagulant unit/ml was observed to be 2.47 mumole/min/ml. Conditions for plasma prekallikrein activation were optimized to approach complete activation when compared to the amido...

متن کامل

A High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma

A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...

متن کامل

DEVELOPMENT OF A SIMPLE AND SENSITIVE ENZYME- LINKED IMMUNOSORBENT ASSAY (ELISA) FOR CLINICAL MEASUREMENT OF TESTOSTERONE USING PENICILLINASE AS LABEL

An enzyme-linked immunosorbent assay using a homologous combination of antiserum raised against testosterone-3-0-carboxymethyloxime-bovine serum albumin (T-3-0-CMO-BSA ) and penicillinase-labelled T-3-0-CMO was developed. This assay was utilized to measure testosterone in serum samples of male and female subjects. The sensitivity of the assay is 50pg/well and the antibody developed crossrea...

متن کامل

17α-Hydroxy-4-pregenen-3-one (17 αP) assay, using acetylcholinesterase enzyme as tracer

17a-hydroxy-4-pregnen-3-one (17aP) hormone is a precursor of other steroid hormones and radioimmunoassay has already been used to measure it, but a simple and rapid "Enzyme Linked Immunosorbant Assay" (ELISA) is described and validated here. A general procedure for prepara-tion of the acetylcholinesterase labelled steroid is described, which is applicable to any steroid. Use of acetyl...

متن کامل

DEVELOPMENT OF A RAPID AND SENSITIVE RADIOIMMUNOASSAY FOR MEASUREMENT OF AFLATOXIN B 1 IN BIOLOGICAL SAMPLES

Aflatoxin B I (AFB) isa well known hepatocarcinogen in several animal species and probably a causative agent in human hepatocellular carcinoma. Humans are exposed to AFB by ingesting contaminated food. Aflatoxin contamination encountered in human foods is usually at low levels which is difficult to measure by chromatographic methods. Therefore in the present study we have developed an immun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Blood

دوره 63 1  شماره 

صفحات  -

تاریخ انتشار 1984