Comparison of a radiofrequency-based wireless pressure sensor to swan-ganz catheter and echocardiography for ambulatory assessment of pulmonary artery pressure in heart failure.
نویسندگان
چکیده
OBJECTIVES The goal of this work was to evaluate the accuracy of a new heart failure (HF) sensor (HFS) (Heart Failure Sensor, CardioMEMS Inc., Atlanta, Georgia) pulmonary artery pressure (PAP) monitoring compared with Swan-Ganz (SG) (Hospira, Inc., Lake Forest, Illinois) catheterization and echocardiography (ECHO) in ambulatory HF patients. BACKGROUND There is an increasing interest in the development of ambulatory monitoring devices aiming to adjust therapy and prevent hospitalizations in HF patients. METHODS Twelve patients with HF and New York Heart Association functional class II to IV were included in this study. The HFS was deployed into the pulmonary artery under angiography, allowing wireless PAP measurement. Two independent blind operators performed 3 HFS measurements at each visit, with simultaneous ECHO at 2, 14, 30, 60, and 90 days. Swan-Ganz catheterization was performed at 0 and 60 days. Linear regression was used as a measure of agreement. Variability between methods and interobserver variability were evaluated by Bland-Altman analysis. RESULTS Mean age was 63 +/- 14.6 years. Systolic PAP was 64 +/- 22 mm Hg and 58 +/- 22 mm Hg for HFS and SG, respectively (p < 0.01). Both methods showed a significant correlation (r2 = 0.96 baseline, r2 = 0.90 follow-up, p < 0.01), with a mean difference of 6.2 +/- 4.5 mm Hg. Diastolic PAP was 23 +/- 14 mm Hg and 28 +/- 16 mm Hg for HFS and SG, respectively (r2 = 0.88 baseline, r2 = 0.48 follow-up, p < 0.01), with a mean difference of -1.6 +/- 6.8 mm Hg. Systolic PAP was 60 +/- 20 mm Hg and 62 +/- 12 mm Hg for HFS and ECHO, respectively (r2 = 0.75, p < 0.01), with a mean difference of -2.6 +/- 11 mm Hg. There was no significant interobserver difference. CONCLUSIONS The HFS provides an accurate method for PAP assessment in the intermediate follow-up of HF patients.
منابع مشابه
Echocardiographic estimation of mean pulmonary artery pressure in critically ill patients
BACKGROUND Indirect assessment of mean pulmonary arterial pressure (MPAP) may assist management of critically ill patients with pulmonary hypertension and right heart dysfunction. MPAP can be estimated as the sum of echocardiographically derived mean right ventricular to right atrial systolic pressure gradient and right atrial pressure; however, this has not been validated in critically ill pat...
متن کاملA Noninvasive Alternative to Swan-Ganz Catheter
Background—Although several studies have demonstrated a good correlation between Doppler echocardiographic and invasive measurements of single hemodynamic variables, the accuracy of echocardiography in providing a comprehensive assessment in individual patients has not been validated. The aim of this study was to assess the accuracy and clinical applicability of Doppler echocardiography in dete...
متن کاملDoppler echocardiography in advanced systolic heart failure: a reliable noninvasive alternative to Swan-Ganz catheter
Background: Although several studies have demonstrated a good correlation between Doppler echocardiographic and invasive measurements of single hemodynamic variables, the accuracy of echocardiography in providing a comprehensive assessment in individual patients has not been validated. To assess the accuracy and clinical applicability of Doppler echocardiography in determining the entire hemody...
متن کاملHaemodynamic parameters obtained by transthoracic echocardiography and Swan-Ganz catheter: a comparative study in liver transplant patients.
OBJECTIVE To compare the haemodynamic measurements of cardiac output (CO), central venous pressure (CVP), pulmonary capillary wedge pressure (Pw) and pulmonary artery systolic pressure (PASP), obtained by Swan-Ganz catheter and transthoracic echocardiography. MATERIAL AND METHODS Prospective study in a Medical/Surgical Intensive Care Unit (ICU). A total of 41 post liver transplant patients we...
متن کاملUnexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report
BACKGROUND Pressure and waveform at the catheter tip are continuously monitored during catheterization of pulmonary artery to ensure accurate catheter placement. We present a case in which pulmonary venous blood was unexpectedly collected from the pulmonary artery catheter despite pulmonary artery pressure and waveform detection at the catheter tip, and describe the measures taken to correct th...