The radioactive waste containers, containing different radioactive materials, have to be characterized before their final disposal. Destructive methods, although being the most precise, are also the most expensive and not the easiest ones from the radioprotection point of view. In this situation, high resolution gamma spectrometry proved to be a reliable method for the non destructive assay method. However, the non-homogenous composition of the radioactive waste inside the drum makes the quantitative characterization of the radioactive waste drum a difficult task. The efficiency calibration procedure is difficult and dependent on different parameters such as: experimental set-up, the sources distribution inside the drum, and also on the nuclear data used for the calculations. The experimental studies complemented with the performed Monte Carlo calculations are presented in this paper.
منابع مشابه
Producing 65Zn and 60Co gamma sources for energy and efficiency calibration of gamma spectrometry systems
Precise calibration of energy and efficiency of gamma spectrometry systems for different geometries is very important. In most cases, preparation of these sources for educational and research centers is very difficult due to high costs and lack of access to the reactor. The purpose of this paper is to explain the procedure for production of calibration sources 65Zn and 60Co using instrumental ...
متن کاملBASIC ASPECTS CONCERNING THE VALIDATION OF THE MEASURING METHOD USING A NEW SPECTROMETRIC GAMMA SYSTEM WITH HPGe DETECTOR
Because of the major impact of the radioactive materials on the environment, their characterization methods have to be well defined, complete and agreed by the control bodies and the civil society. The paper presents measurements of certified etalon gamma emitting radiation sources, in order to perform the energy and the efficiency calibration of a new HPGe spectrometric system, and to determin...
متن کاملGamma-spectrometric uranium age-dating using intrinsic efficiency calibration
A non-destructive, gamma-spectrometric method for uranium age-dating is presented which is applicable to material of any physical form and geometrical shape. It relies on measuring the daughter/parent activity ratio Bi/U by low-background, high-resolution gamma-spectrometry using intrinsic efficiency calibration. The method does not require the use of any reference materials nor the use of an e...
متن کاملEnvironmental gamma spectrometry for Polish Nuclear Power Plant – preliminary considerations
Poland faces a choice of an environmental radiation monitoring systems (ERMS) for newly designed Nuclear Power Plant (NPP). Contemporary radiation monitoring systems can be based on gamma detector cooperated with Multichannel Analyzer (MCA). This solution will give a tool for very fast assessment of radiological situation around NPP and allows authority to react in case of radiological circumst...
متن کاملروشی جدید برای اندازهگیری پارامترهای چشمههای آلفازای فوق اورانیوم
An alpha-gamma coincidence method, using multi-parameter analyzer (MPA) system in list mode was used for measuring parameters of transuranium sources. The benefit of using the list method is preventing duplication of experiments a lot and thus saving the cost and time taken for this type of testing that due to very small sample rate, spend a lot of time. The multi-parameter analyzer stores the ...
متن کاملذخیره در منابع من